EN
14365216.02 08/2020 EN/DE
Operating instructions magnetostrictive level transmitter, models FLM-CA, FLM-CM
24
9. Specifications
9.1 Model FLM-CA
Magnetostrictive level transmitter, model FLM-CA
Guide tube
■
Ø 6 mm (max. 1,000 mm)
■
Ø 12 mm (max. 3,000 mm)
Process connection
Mounting thread downwards
■
G 1/2 ... G 2
■
1/2 NPT ... 2 NPT
Mounting flange
■
ANSI 1/2" ... 2 1/2", class 150 ... 600
■
EN DN 20 ... DN 65, PN 6 ... PN 100
■
DIN DN 20 ... DN 65, PN 6 ... PN 100
Other process connections on request
Materials
Wetted parts
Stainless steel 1.4571 (316Ti)
Connection head
Stainless steel 1.4305 (303)
Insertion length
Guide tube Ø 6 mm
100 ... 1,000 mm
Guide tube Ø 12 mm
100 … 3,000 mm
Measurement accuracy
±1.25 mm
Resolution
0.1 mm
Electrical connection
Connection terminals max. 1.5 mm²
Supply voltage
DC 8 ... 30 V
Output signal
■
4 ... 20 mA (NAMUR NE43)
■
HART
®
ver. 6
Vibration resistant version (option)
to 4 g (only for guide tube Ø 12 mm)
Operating pressure
Depending on the float, max. 40 bar
Operating temperature
Guide tube Ø 6 mm
-40 ... +125 °C
Guide tube Ø 12 mm
-40 ... +250 °C
Ambient temperature
-40 ... +85 °C
Ingress protection per EN 60529
IP68
Configuration
Version without HART
®
protocol
Via two built-in buttons in the connection housing
Version with HART
®
protocol
Via two built-in buttons, HART
®
communicator or HART
®
interface in the connection housing
For further specifications see data sheet LM 20.04 and the order documentation.
9. Specifications