EN
WIKA operating instructions DELTA-plus, DELTA-comb and DELTA-switch
9
14532078.01 12/2021 EN/DE
3. Specifications
3. Specifications
The insulation values (air gaps and creepage distances) are sized for the fol-
lowing ambient conditions in accordance with EN 61010-1:2010:
Altitude up to 2,000 m
Overvoltage category II
Pollution degree 2
Relative humidity 0 ... 95 % non-condensing (per DIN 40040)
The strength of the measuring instruments (enclosing, non-metal components)
was tested with a reduced impact energy of 2 J corresponding to IK07 in ac-
cordance with EN 61010-1:2010. The IK code is included on the respective
product label.
Specifications
DELTA-plus, model DPG40 and
DELTA-comb, model DPGS40
Nominal size
Differential pressure indication: Ø 100 mm
Working pressure indication: Ø 22 mm
Accuracy
Differential pressure indication: ≤ 2.5 % of span
(option ≤ 1.6 %)
Working pressure indication: ≤ 4 % of span
Scale ranges
(EN 837)
Differential pressure: 0 ... 0.16 to 0 ... 10 bar for model
DPG40
Differential pressure: 0 ... 0.25 to 0 ... 10 bar for model
DPGS40
Working pressure: 0 ... 25 bar
Max. working pressure (stat.)
25 bar
Overload safety
Max. 25 bar
On one, both and alternatingly on the ⊕ and ⊖ sides
Permissible temperatures
Ambient: -10 ... +70 °C, medium: -10 ... +90 °C
Storage: -40 ... +70 °C
Ingress protection
IP65 per IEC/EN 60529
Measuring chamber (wetted)
Aluminium, EN AC–Al Si9Cu3(Fe), black painted
(option: stainless steel)
Process connections (wetted)
2 x G 1/4 female thread, lower mount, in-line, centre
distance 26 mm
Pressure elements (wetted)
Differential pressure: Compression springs from
stainless steel 1.4310 and separating diaphragm
from FPM/FKM (option: NBR)
Working pressure: Bourdon tube from Cu alloy
Transmission parts (wetted)
Stainless steel 1.4301, 1.4305, 1.4310, FPM/FKM
(option: NBR)