3. Specifications
Electrical contact
Type of contact
Microswitch
Contact function
Single change-over contact
Double change-over contact
Contact model 850.3
Contact model 850.3.3
Load data
U max., I max., P max.
AC 250 V, 5 A, 250 VA DC 30 V, 0.4 A, 10 W
Switch point setting
from the outside at assistant scale by means of
adjustment screw(s)
Setting range
from 10 % to 100 % of the full scale value
Switch point reproducibility
≤ 1.6 %
Switch hysteresis
max. 5 % of the full scale value (option: max. 2.5 %)
Electrical connection
Cable gland M20 x 1.5 with 1 m free cable