5 Managing Switch
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
33
5.2
Web Browser Configuration
The Switch has an HTML based user interface embedded in the flash memory. The interface offers an easy
to use means to manage basic and advanced switch functions. The interface allows for local or remote
switch configuration anywhere on the network.
The interface is designed for use with [Internet Explorer (6.0), Chrome, Firefox].
5.2.1
Preparing for Web Configuration
The interface requires the installation and connection of the Switch to the existing network. A PC also
connected to the network is required to connect to the Switch and access the interface through a web
browser. The required networking information is provided as follows:
IP address: 10.0.50.2
Subnet mask: 255.255.255.0
Default gateway: 10.0.50.254
User name: admin
Password: wienet123