4
Function Diagram
FD 0221-6 W1
A1 Power Supply, LED SUPPLY
A2 Power Supply
Y2 Reset
K1, K2 and LED K1,K2
13/14, 23/24
t
A
t
M
Emergency Stop
single channel
t
R
Emergency Stop
two channel
t
A
= Response time
t
R
= Release time
t
M
= Min. switch-on time
Technical data
Supply
Rated voltage U
N
DC 24 V
AC 24 V
Rated power DC / AC
1 W
1 W
Rated power AC
---
1 VA
Residual ripple U
SS
2,4 V
--
Rated frequency
50 Hz to 60 Hz
Operating range
0.85 to 1.1 x U
N
Control circuit
Isolation between A1, A2 and Y1
no
Rated output voltage only to supply the inputs
DC 24 V
Response time t
A
K1, K2
20 ms
Release time t
R
by emergency stop
K1, K2
50 ms
Minimum switch-on time t
M
by Y2
30 ms
Output circuit
Contacts
2 NO safety contacts positively driven
Switching voltage U
n
AC/DC 230 V
Max. rated current I
n
/ safety contact
4 A
Max. total current for all contacts
8 A
Application category according EN 60947-5-1
AC-15: Ue AC 230 V, Ie 3 A
DC-13: Ue DC 24 V, Ie 3 A
Short-circuit protection
fuse element max. 4 A type gG
General data
Test voltage
300 V
Rated surge voltage
4 kV
Protection degree Housing/Terminals acc. EN 60529
IP 40 / IP 20
Isolation
Creepage and clearance between circuits
acc. EN 60664-1
Contamination level
3 external, 2 internal
Ambient temperature working range / storage range
-25°C to +55°C / -25°C to +75°C
Weight
0.2 kg
Terminals and connection
Single-core or finely stranded
1 x 0.14 - 2.5 mm² / 2 x 0.14 - 0.75 mm²
Stripping length
max. 8 mm
Finely stranded with wire-end ferrule to DIN 46228
1 x 0.25 - 2.5 mm² / 2 x 0.25 - 0.5 mm²
Max. tightening torque
0.5 to 0.6 Nm