![Wieland samos PRO COMPACT Manual Download Page 84](http://html1.mh-extra.com/html/wieland/samos-pro-compact/samos-pro-compact_manual_979665084.webp)
Technical data
Wieland Electric GmbH | BA000966 | 08/2017 [8151]
84
Safety technology reference values
938446475
Controller modules without I/O expansion
888559243
Table 54: Safety technology reference values for samosPRO COMPACT (without I/O expansion)
Characteristic values
Configuration of safety outputs
Output groups:
Q1/Q2, Q3/Q4, IQ1/IQ2, IQ3/IQ4
Safety Integ-
rity Level
(IEC 61508)
1
Category
(EN ISO
13849-1)
Performance
level
(EN ISO
13849-1)
1
PFHd
2
Single-
channel
or two-
channel
input
Two-channel outputs (with or without
test pulses)
SIL3
4
PL e
1.3 · 10
–9
Single-
channel
output Q
n
for an out-
put group
Test pulses at all outputs
of an output group acti-
vated
SIL3
4
PL e
1.4 · 10
–9
Test pulses at one output
of the output group acti-
vated and test pulses at
the other output of the
output group deacti-
vated.
The value indicated refers
to the output with acti-
vated test pulses.
SIL3
3
PL e
1.4 · 10
–9
Output test pulses deac-
tivated
SIL2
3
PL d
9.8 · 10
–9
1
For detailed information regarding the safety configuration of your machine/system, please
contact the Wieland Electric branch in charge of your area.
2
Average probability of a hazardous-causing failure per hour
12.2
12.2.1
Summary of Contents for samos PRO COMPACT
Page 1: ...samos PRO samos PRO COMPACT Hardware Manual Doc no BA000966 Last Update 08 2017 8151...
Page 103: ...Appendix Wieland Electric GmbH BA000966 08 2017 8151 103 Declaration of Conformity Page 2...
Page 104: ...Appendix Wieland Electric GmbH BA000966 08 2017 8151 104 Declaration of Conformity Page 3...
Page 105: ...Appendix Wieland Electric GmbH BA000966 08 2017 8151 105 Declaration of Conformity Page 4...