![Wieland samos PRO COMPACT Manual Download Page 111](http://html1.mh-extra.com/html/wieland/samos-pro-compact/samos-pro-compact_manual_979665111.webp)
Appendix
Wieland Electric GmbH | BA000966 | 08/2017 [8151]
111
Error No.
Error type Logbook message
System behavior
Remedy
15000001
Error
The CRC could not be calculated
correctly
-
Repeat
support request
15000002
Error
Failed to generate report
-
Repeat
support request
22010140
Warning
Error in system configuration
System continues to
run
Reload system confi-
guration
220101F5
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
220101F6
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
220101F7
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
220101F8
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
220101F9
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
220101FA
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
220101FC
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
22010226
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
22010227
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
22010228
Warning
Error in system configuration
Configuration requi-
red
Reload system confi-
guration
22010231
Warning
Pulse period 0 must have pulse
length 0.
Configuration requi-
red
Change system con-
figuration and reload
22010232
Warning
Pulse length must be <= pulse peri-
od/2.
Configuration requi-
red
Change system con-
figuration and reload
22010233
Warning
Impermissible test period (permissib-
le: 0,40,200,400,600,800,1000).
Configuration requi-
red
Change system con-
figuration and reload
22010234
Warning
Pulse length must be 4..100ms in
increments of 4ms
Configuration requi-
red
Change system con-
figuration and reload
22010240
Warning
Maximum count of function blocks
or mapping exceeded
Configuration requi-
red
Change system con-
figuration and reload
22010241
Warning
The number of IO modules is diffe-
rent in the configuration
Configuration requi-
red
Change system con-
figuration and reload
22010242
Warning
The number of Gateway modules is
different in the configuration
Configuration requi-
red
Change system con-
figuration and reload
22010244
Warning
The type or major version of the I/O
module is inappropriate for the pro-
ject
Configuration requi-
red
Change system con-
figuration and reload
22010245
Warning
The type or major version of the
gateway module is inappropriate for
the project
Configuration requi-
red
Change system con-
figuration and reload
22010250
Warning
The press function components are
not supported by this device version
Configuration requi-
red
Change system con-
figuration and reload
22011243
Warning
Incorrect device name or safety
category of the module
Configuration requi-
red
Change system con-
figuration and reload
22012243
Warning
Incorrect module type
Configuration requi-
red
Change system con-
figuration and reload
Summary of Contents for samos PRO COMPACT
Page 1: ...samos PRO samos PRO COMPACT Hardware Manual Doc no BA000966 Last Update 08 2017 8151...
Page 103: ...Appendix Wieland Electric GmbH BA000966 08 2017 8151 103 Declaration of Conformity Page 2...
Page 104: ...Appendix Wieland Electric GmbH BA000966 08 2017 8151 104 Declaration of Conformity Page 3...
Page 105: ...Appendix Wieland Electric GmbH BA000966 08 2017 8151 105 Declaration of Conformity Page 4...