08.10.14 Working
instructions
WIDOS RSC 2000
Page 24 of 63
4.7.2. How
to
adjust
the pressure regulator:
Pull the pressure setting button upwards (away from the housing).
Turn the pressure setting button until the desired pressure is shown on the manometer. The
input pressure must be at least 1 bar higher than the output pressure.
Press the pressure setting button downwards (towards the housing) to secure it against
unintentional turning.
4.8. Vacuum
Make sure that the vacuum is connected to the power socket at the machine and that the
vacuum switch is activated.
Switch the vacuum in the manual mode via the button on the operator panel: <
>.
Do not start the vacuum without installed chip bag.
Select by the knob which of the two chip bags you intend to fill.
By the manually vacuum hose you can vacuumthe remain chips.
Remove the stopper for vacuum previously.
Please consult the separately enclosed working instruction of the vacuum AF22 for its
operation, maintenance, repair etc.
Brackets for the chip bags
Filter bag
Connection vacuum hose to vacuum automatically
Socket for vacuum
Switch for vacuum
Knebel
Connection vacuum hose to manuel vacuum
Chip bags