Ku nst sto ffschweißtec hni k
Starting and operating
Chapter 5
02.08.2011
Working Instructions WIDOS 4900 CNC 3.5
Page 26 of 68
5.10.1. Setting the pipe data
Display:
2
nd
line:
WIDOS 4900 CNC
22.11.2000 10:10
The type of the machine is displayed
Current date and time
button <Start> for welding process
Display:
2
nd
line:
mat diam wall temp
PE80 225 20.5 206°
The last welding parameters are displayed
button <+> or <
−
>: change the respective value
button <Start>: confirm and jump to the next parameter
Display:
2
nd
line:
mat diam wall temp
PE80 225 20.5 206°
button <+> or <
−
>: change the respective value
button <Start>: confirm and jump to the next parameter
Display:
2
nd
line:
mat diam wall temp
PE80 225 20.5 206°
button <+> or <
−
>: change the respective value
button <Start>: confirm and jump to the next parameter
Display:
2
nd
line:
mat diam wall temp
PE80 225 20.5 206°
Display of the heating element temperature
calculated according to the prescriptions of the DVS
button <Start>: back to basic menu
Display:
2
nd
line:
WIDOS 4900 CNC
22.11.2000 10:10
Basic menu