Timer Button 

 

 

 

10

Display Screen

 

 

 

 

 

 

 

 

 

 

 

 

Unit Features and Alerts 

 

Bucket Level Light 

Bucket level indicator light will illuminate when the bucket is full and needs to be emptied. This  
light will also illuminate when the bucket is removed or not properly inserted. The dehumidifier  
shuts off within 30 seconds of the indicator light illuminating. 

Auto Shut Off 

When the selected humidity level is reached, the dehumidifying function will shut off automatically 
and the fan will run continuously. 

Auto Defrost 

In the event frost builds up on the evaporator coils, the compressor will cycle off and the fan will 
continue to run until the frost is evaporated. 

Three Minute Cycle Down Function

  

After the unit has stopped, it cannot be restarted for 3 minutes. This is to ensure the unit  
completes its cycles down before reactivation.  

Auto-Restart  

In the event of a power outage, unit restarts at the previously set function mode and settings when 
power is restored. 

Setting the Timer (Auto-start/stop) 

Setting Auto Stop timer 
With the unit is operating in any function mode, press the TIMER button. The TIME OFF light will  
come on. Then set the desired time delay OFF hours by pressing the 

 and 

 buttons. The time 

increments are at 0.5 hour to up to 10 hours, then at 1 hour to 24 hours. When the delay time set  
has elapsed, the unit switches off.  To cancel the delayed switch off function, turn off the unit. 
Setting Auto Start timer 
With the unit is turned off, press the TIMER button. The TIME ON light will come on. Then set the 
desired time delay OFF hours by pressing the 

 and 

 buttons. The time increments are at 0.5  

hour to up to 10 hours, then at 1 hour to 24 hours. When the delay time set has elapsed, the unit 
switches on.  To cancel the delayed switch off function, turn off the unit. 
When the Auto start & Auto stop times are set within the same program sequence, TIME ON and 
TIME OFF indicator lights illuminate identifying both ON and OFF times are programmed. 
When the display shows P2, the Auto Stop/ Start function is canceled. 

    

   Silver Ion Air Filter 

Your Whynter dehumidifier is equipped with an advanced Silver Ion air filter which is designed to  
not only trap dust and large particles but also kills bacteria in the air and controls the growth of 
microbes, such as virus, fungi and spores. 

 

 

                                                            

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

10. Display Screen 
The display screen shows a number of different indications depending on the selection function. 

 

Shows the set % relative humidity level from 35%RH to 85%RH. 

 

Shows auto start/stop time (0~24 hours). 

 

After the option settings are completed, the display shows the approximate room humidity level in a 
range of 30%RH (Relative Humidity) to 90%RH 

The display screen may also display the following alerts: 
Error Codes and Protection Codes: 
AS- Humidity sensor error: Power off the unit, then unplug it for 15 minutes. Plug in and power on. If error 
repeats, call for service. 
ES- Temperature sensor error:  Power off the unit, then unplug it for 15 minutes. Plug in and power on. If error 
repeats, call for service. 
P1- Unit is defrosting:  Allow the unit time to defrost. The error will clear after the unit is self-defrosted. 
P2- Bucket is full or bucket is not in right position:  Empty the water bucket and reinstall it properly.  
E1- Unit Error: Power off the unit, then unplug it for 15 minutes. Plug in and power on. If error repeats, call for 
service.

 

 

Summary of Contents for RESIDENTIAL PORTABLE DEHUMIDIER RPD-401W

Page 1: ...Instruction Manual MODEL RPD 401W RPD 651W Congratulations on your new WHYNTER product Please read this Instruction Manual carefully before using the product to ensure proper operation Keep this manu...

Page 2: ...Unit features and alerts 7 IDENTIFICATION OF PARTS Identification of parts 8 AIR FILTER INSTALLATION Installation the air filters 9 OPERATING THE UNIT Positioning the unit 10 Removing the collected w...

Page 3: ...d collecting the condensation water in the internal water bucket or draining through a drain hose Please keep this user manual in a safe place for future reference DISPOSAL This symbol on the product...

Page 4: ...leave it in an upright position for at least 2 hours before first use This appliance must be installed in an area protected from the element such as wind rain water spray or drips When using this appl...

Page 5: ...dehumidifying coils The coils condense or draw moisture from the air and air flows through the side louvers into the room as dry warm air Moisture removed from air is collected in a water bucket on th...

Page 6: ...ontinue indicator light will come on when this mode is selected 4 Filter Reset Button The check filter feature is a reminder to clean the air filter for efficient operation Filter indicator light will...

Page 7: ...e and buttons The time increments are at 0 5 hour to up to 10 hours then at 1 hour to 24 hours When the delay time set has elapsed the unit switches on To cancel the delayed switch off function turn o...

Page 8: ...erent but the operations and functions are the same 1 Model RPD 651W Model RPD 401W Front Above 1 Control Panel 2 Air Intake Grille Rear Below 3 Air Outlet Vent 1 Drain Hose Outlet 4 Handle 2 Casters...

Page 9: ...the air and controls the growth of microbes such as virus fungi and spores It is recommended you replace the Silver Ion Filter every two to three months or as needed Follow the steps below to install...

Page 10: ...rmance Allow at least 10 of air space on all sides of the unit for good air circulation NOTE When using the dehumidifier for the first time operate the unit continuously for 24 hours This unit is desi...

Page 11: ...y cause the unit to malfunction When the bucket is removed check if there is any excess water at the base of the unit Wipe any visible water inside the unit before replacing the bucket 2 Continuous dr...

Page 12: ...o assure that your dehumidifier runs efficiently it is recommended to clean the air filter at least once every two weeks Remove the bucket and pull filter downwards Fig 10 Use a vacuum cleaner or tap...

Page 13: ...day EEV Liters per kW Hour 1 5 1 8 Power supply 115v 60Hz 115v 60Hz Maximum power input 490 Watts 710 Watts Maximum input 4 8 Amps 6 6 Amps Refrigerant R 134A R 410A Air flow M3 H CFM 270 220 370 330...

Page 14: ...l windows or doors You may need an additional dehumidifier for area Clean the air filter The unit must be placed in a space that does not restrict air flowing into the rear coil or out of the front gr...

Page 15: ...g or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to...

Reviews: