Summary of Contents for Air DMD36

Page 1: ...0607 MODEL NO DMD36 PART No 6470640 OPERATION MAINTENANCE INSTRUCTIONS DEHUMIDIFIER DEHUMIDIFIER ...

Page 2: ...proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights The DMD36 is equipped with AUTO SENSING DUAL VOLTAGE SELECTI...

Page 3: ...the plug to stop or start the machine Use the ON OFF switch on the side of the unit Never pull on the mains cable to pull the plug from the socket or to move the machine WARNING Read these safety instructions before using the equipment Always transport store and operate this equipment in an upright position DO NOT lay the unit on its side Always leave the unit to stand for 15 minutes minimum befor...

Page 4: ...ly proceed as follows Connect GREEN YELLOW coloured cord to plug terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN YELLOW Connect BROWN cord to terminal marked with a letter L or coloured RED Connect BLUE cord to terminal marked with a letter N or coloured BLACK Fuse Rating The fuse in the plug must be replaced with one of the same rating 10amp and this replacement must be...

Page 5: ...unter which is not resettable Before switching the dehumidifier ON take a note of the hours run counter to assist with monitoring the amount of time the unit is run After moving the dehumidifier into the location to be used allow the unit to stand for 15 minutes before switching it on Ensure all doors and windows are closed and the area sealed where possible this aids to speed the dehumidification...

Page 6: ... Temperature outside of specified operating range Coils Dirty If the fuse blows repeatedly consult your Clarke dealer for advice 6 Water leaking Blocked drain hose Water receptacle full and overflowing Drain hose higher than the outlet port Unit has been moved without draining the inner drip tray Unit iced up Clear blockage Adjust the hose level check the water flows Ensure the drip tray is empty ...

Page 7: ...l 1 5 BW020350 Lower Case 1 6 ME040207 Cable Gland 1 7 EL020113 Mains Cable 1 8 EL030103 Push Button Switch 1 9 EL030411 Hour Clock 1 10 ME010215 Caster 1 11 EL030510 Timer 1 12 FR010104 Compressor 1 13 FR010404 Soenoid Coil 1 14 FA040204 Fan Motor Assembly 1 15 EL030209 Switching Relay 1 16 EL030608 Transformer 1 17 FR020302 Filter Drier 1 18 EL030906 Resistor 1 19 EL040101 Fuse Holder 1 20 FR030...

Page 8: ...PARTS DIAGRAM 8 ...

Page 9: ...the motor spins freely Reassemble the unit in the reverse order IMPORTANT When carrying out maintenance activities precautions to ensure the safety of yourself and that of others around you must be considered i e choose a location where it is safe to use compressed air to blow the unit out and always wear safety glasses and ear defenders STORAGE Switch OFF the power supply and disconnect from the ...

Reviews: