background image

12 | 

P a g e

 

 

 

 

 

 

CARE AND MAINTAINCE 

ALWAYS turn off and unplug the dehumidifier before cleaning. 

 

 

1.  Cleaning the air grille and main unit 

 

Use a damp cloth to wrap the main unit or use water and a mild detergent. Do not use bleach, 
chemicals or abrasives. 

 

Do not splash water directly onto the unit. Doing so may cause an electrical shock, cause the 
insulation to deteriorate, or cause the unit to rust. 

 

Use a vacuum attachment or brush to clean the air intake and outlet grilles. 

2.  Cleaning the bucket 

Clean the bucket to prevent growth of mold, mildew and bacteria every two weeks.  

 

Fill the bucket with clean warm water and add mild detergent to the water.  

 

Dry thoroughly before reinserting the bucket to the main unit. 

NOTE: 

Do not clean the bucket in a dishwasher.  

 

3.  Cleaning the air filter 

To ensure the air intake is filtered properly and to assure that your  
dehumidifier runs efficiently, it is recommended to clean the air filter  
at least once every two weeks. 

 

Remove the bucket and pull filter downwards. (Fig 10) 

 

Use a vacuum cleaner or tap the filter lightly to remove loose dust  
and dirt. 

 

Rinse the air filter under warm or cold running water  
(no hotter than 100F.) 

 

Dry thoroughly before reinserting the air filter. 

 

Reinstall the air filter and replace bucket securely. 

 

CAUTION:

 

NEVER operate the dehumidifier without an air filter in place.  

 

 
 
 

 

 

 

4. End of Season Storage 

  After turning off the unit, wait 24 hours before emptying the bucket to allow excess moisture to drain 

into the bucket. 

  Clean the main unit, water bucket and air filter as detailed above. 

  Wrap the cord around the power cord bracket (Fig.12a) or wrap the cord and secure it with the 

power cord strap (Fig.12b). 

  Cover the unit with the original plastic bag that came with the unit or any appropriate dust cover. 

  Store the unit upright in a dry, well-ventilated place. 

 

 

 

Fig. 12a 

Fig. 12b 

 

Model: RPD-651W   

 

 

Model: RPD401W 

 

 
 
 
 
 
 

Fig 10 

Summary of Contents for RESIDENTIAL PORTABLE DEHUMIDIER RPD-401W

Page 1: ...Instruction Manual MODEL RPD 401W RPD 651W Congratulations on your new WHYNTER product Please read this Instruction Manual carefully before using the product to ensure proper operation Keep this manu...

Page 2: ...Unit features and alerts 7 IDENTIFICATION OF PARTS Identification of parts 8 AIR FILTER INSTALLATION Installation the air filters 9 OPERATING THE UNIT Positioning the unit 10 Removing the collected w...

Page 3: ...d collecting the condensation water in the internal water bucket or draining through a drain hose Please keep this user manual in a safe place for future reference DISPOSAL This symbol on the product...

Page 4: ...leave it in an upright position for at least 2 hours before first use This appliance must be installed in an area protected from the element such as wind rain water spray or drips When using this appl...

Page 5: ...dehumidifying coils The coils condense or draw moisture from the air and air flows through the side louvers into the room as dry warm air Moisture removed from air is collected in a water bucket on th...

Page 6: ...ontinue indicator light will come on when this mode is selected 4 Filter Reset Button The check filter feature is a reminder to clean the air filter for efficient operation Filter indicator light will...

Page 7: ...e and buttons The time increments are at 0 5 hour to up to 10 hours then at 1 hour to 24 hours When the delay time set has elapsed the unit switches on To cancel the delayed switch off function turn o...

Page 8: ...erent but the operations and functions are the same 1 Model RPD 651W Model RPD 401W Front Above 1 Control Panel 2 Air Intake Grille Rear Below 3 Air Outlet Vent 1 Drain Hose Outlet 4 Handle 2 Casters...

Page 9: ...the air and controls the growth of microbes such as virus fungi and spores It is recommended you replace the Silver Ion Filter every two to three months or as needed Follow the steps below to install...

Page 10: ...rmance Allow at least 10 of air space on all sides of the unit for good air circulation NOTE When using the dehumidifier for the first time operate the unit continuously for 24 hours This unit is desi...

Page 11: ...y cause the unit to malfunction When the bucket is removed check if there is any excess water at the base of the unit Wipe any visible water inside the unit before replacing the bucket 2 Continuous dr...

Page 12: ...o assure that your dehumidifier runs efficiently it is recommended to clean the air filter at least once every two weeks Remove the bucket and pull filter downwards Fig 10 Use a vacuum cleaner or tap...

Page 13: ...day EEV Liters per kW Hour 1 5 1 8 Power supply 115v 60Hz 115v 60Hz Maximum power input 490 Watts 710 Watts Maximum input 4 8 Amps 6 6 Amps Refrigerant R 134A R 410A Air flow M3 H CFM 270 220 370 330...

Page 14: ...l windows or doors You may need an additional dehumidifier for area Clean the air filter The unit must be placed in a space that does not restrict air flowing into the rear coil or out of the front gr...

Page 15: ...g or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to...