Do not, under any 

circumstances, cut, 

remove, or bypass 

the grounding prong.

 

 
 
 
 
 
 

 

 

 

This unit is grounded through the 

power cord plug when plugged 

into a matching wall outlet.

 

Electrical Information 

 

The appliance is equipped with a three-prong grounded plug 

on the power cord for your protection. Never modify, 
remove or attempt to repair the plug yourself. 

 

Do not pull the unit by the power cord or pull on the cord to 

unplug the unit. Grip the plug and pull it away from the wall 
receptacle. 

 

Ensure the power cord is not tangled, knotted or otherwise 

distorted before operating the unit. 

 

The dehumidifier must be plugged directly into a properly 

grounded wall outlet receptacle. If the wall receptacle you 
intend to use is not adequately grounded or protected by a 
time delay fuse or circuit breaker, have a qualified 
electrician install an outlet that is appropriate to local 
electrical codes and requirements.  

 

Do not use extension cords, power strips or an adapter plug 

with this unit 

 

Always unplug the unit before opening, installing or servicing. 

 

How it Works 

When the dehumidifier is started, the fan begins to pull moisture-laden air across the dehumidifying 
coils. The coils condense or draw moisture from the air, and air flows through the side louvers into the 
room as dry, warm air. Moisture removed from air is collected in a water bucket on the front of the 
dehumidifier. 
The unit is designed to operate between 41°F (5°C), and 96°F (35°C). The "Compressor" circuit has 
an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents 
overheating of the compressor and possible circuit breaker tripping.  Make sure the tank is fitted 
correctly otherwise unit will not turn on. 
 

Energy Saving Guide 

This Whynter dehumidifier is an Energy Star rated appliance. Follow the guide below can help to get 
the best performance and efficiency from your dehumidifier.  

 

Do not cover the air intake and outlet. 

 

Do not place the unit in front of curtains or drapes - to ensure they do not obstruct the air 
intake. 

 

Keep curtains, blinds or drapes closed during the sunniest part of the day.  

 

Close all windows and doors. 

 

Indoor relative humidity should ideally be kept between 35%RH and 60%RH depending on the 
ambient temperature. 

 

Make sure the unit is on a hard and level surf ace. 

 

To prolong the compressor's life, please wait at least 3 minutes before turning the unit back on 
after shutting it off. 

 

Inspect and keep the air filter clean by cleaning regularly. 

 

Perform routine maintenance. 

 
 
 
 
 

Summary of Contents for RESIDENTIAL PORTABLE DEHUMIDIER RPD-401W

Page 1: ...Instruction Manual MODEL RPD 401W RPD 651W Congratulations on your new WHYNTER product Please read this Instruction Manual carefully before using the product to ensure proper operation Keep this manu...

Page 2: ...Unit features and alerts 7 IDENTIFICATION OF PARTS Identification of parts 8 AIR FILTER INSTALLATION Installation the air filters 9 OPERATING THE UNIT Positioning the unit 10 Removing the collected w...

Page 3: ...d collecting the condensation water in the internal water bucket or draining through a drain hose Please keep this user manual in a safe place for future reference DISPOSAL This symbol on the product...

Page 4: ...leave it in an upright position for at least 2 hours before first use This appliance must be installed in an area protected from the element such as wind rain water spray or drips When using this appl...

Page 5: ...dehumidifying coils The coils condense or draw moisture from the air and air flows through the side louvers into the room as dry warm air Moisture removed from air is collected in a water bucket on th...

Page 6: ...ontinue indicator light will come on when this mode is selected 4 Filter Reset Button The check filter feature is a reminder to clean the air filter for efficient operation Filter indicator light will...

Page 7: ...e and buttons The time increments are at 0 5 hour to up to 10 hours then at 1 hour to 24 hours When the delay time set has elapsed the unit switches on To cancel the delayed switch off function turn o...

Page 8: ...erent but the operations and functions are the same 1 Model RPD 651W Model RPD 401W Front Above 1 Control Panel 2 Air Intake Grille Rear Below 3 Air Outlet Vent 1 Drain Hose Outlet 4 Handle 2 Casters...

Page 9: ...the air and controls the growth of microbes such as virus fungi and spores It is recommended you replace the Silver Ion Filter every two to three months or as needed Follow the steps below to install...

Page 10: ...rmance Allow at least 10 of air space on all sides of the unit for good air circulation NOTE When using the dehumidifier for the first time operate the unit continuously for 24 hours This unit is desi...

Page 11: ...y cause the unit to malfunction When the bucket is removed check if there is any excess water at the base of the unit Wipe any visible water inside the unit before replacing the bucket 2 Continuous dr...

Page 12: ...o assure that your dehumidifier runs efficiently it is recommended to clean the air filter at least once every two weeks Remove the bucket and pull filter downwards Fig 10 Use a vacuum cleaner or tap...

Page 13: ...day EEV Liters per kW Hour 1 5 1 8 Power supply 115v 60Hz 115v 60Hz Maximum power input 490 Watts 710 Watts Maximum input 4 8 Amps 6 6 Amps Refrigerant R 134A R 410A Air flow M3 H CFM 270 220 370 330...

Page 14: ...l windows or doors You may need an additional dehumidifier for area Clean the air filter The unit must be placed in a space that does not restrict air flowing into the rear coil or out of the front gr...

Page 15: ...g or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to...

Reviews: