PRECAUTION:  The installer should be an experienced service technician.  Disconnect electrical power before 
beginning installation.  Do not install where temperatures fall below 32 degrees F or where plenum temperatures 
exceed 150 degrees F.  For maximum evaporative capacity, install this humidifier on the warm air supply plenum.

FOR INSTALLATION  ON A VERTICAL

SURFACE OF THE WARM AIR PLENUM

OF ANY FORCED AIR FURNACE

INSTALLER:  PLEASE FILL OUT AND MAIL WARRANTY CARD AFTER INSTALLATION
                      IS COMPLETE.  LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER.

ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper supply tubing for hot water applications
2. 

current sensing relay (G.F. Model #GA50 suggested)

3. junction box, 115 V. grounding outlet, cover and wire
4. 1/2” I.D. drain hose
5. 

#8 self piercing sheet metal screws

1000 SERIES

FLOW THROUGH 

POWER HUMIDIFIER

Select location on vertical surface of warm air plenum of a forced air 
handling system for mounting humidifier that allows for service and 
maintenance.  Do not install humidifier where the blanked off ends of a 
cooling coil will restrict air flow to the humidifier.  Cut out a square section 
12-1/8” tall by 14-1/8” wide as shown.

1

2

2

 

Open cover and remove evaporator pad assembly.  Humidifier chassis is 
self retaining, slide top side in first then slide chassis down. Level chassis 
and install eight screws.

3

COPPER
TUBING

PLASTIC
TUBING

Mount the self tapping saddle valve on either a cold or a hot water pipe.    
A side or top mount is best to avoid clogging from pipe sediment.  
Connect 1/4” O.D. tubing to the saddle valve.  Copper tubing requires a 
brass compression nut and brass sleeve.  Plastic tubing requires a brass 
insert inside the tubing in addition to a plastic ferrule and brass nut.

NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN 
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT. 

 

INSTALLATION OF THIS SADDLE VALVE MUST MEET OR EXCEED 
LOCAL CODES AND ORDINANCES.

Connect  1/4" water supply tube to inlet of solenoid.Connect drain hose 
to 1/2" spout on humidifier cabinet using hose clamp if necessary.  Run 
1/2" hose to suitable drain such as floor drain, sewer or laundry sink.  Be 
sure hose has continuous slope and is not kinked at any point.

4

Fresh Indoor Air Quality

R

FORM NO. 1000-16 REV. E

12-1/8”

14-1/8”

3/4” TEE

1/2” TEE

GCV3412 CODE VALVE INSTALLATION INSTRUCTIONS

Copper Pipe 
 1.   Turn off water supply.
 2.   Clean pipe, fittings and valve with sandpaper or wire brush.
 3.   Apply a thin layer of flux to all surfaces to be soldered.
 4.   Assemble valve to pipe and/or fittings.
 5.   Cooling the valve by wrapping a wetted rag around the valve is  
       optional.
 6.   Heat the joints with a torch. Apply solder to each joint. Continue to  
       apply heat sufficient to keep solder liquid.
 7.   After solder has filled entire joint area, remove heat and allow joint  
       to cool. Do not move or disturb.
 8.   Slide compression nut over 1/4” copper tube followed by  
       compression sleeve.
  9.  Insert tube into valve fully and tighten nut.
10.  Turn on water supply and check for leaks.

*CODE VALVE IS INCLUDED WITH AUTOMATIC MODELS ONLY

Summary of Contents for Elite 1000

Page 1: ... self tapping saddle valve on either a cold or a hot water pipe A side or top mount is best to avoid clogging from pipe sediment Connect 1 4 O D tubing to the saddle valve Copper tubing requires a brass compression nut and brass sleeve Plastic tubing requires a brass insert inside the tubing in addition to a plastic ferrule and brass nut NOTE DO NOT USE PLASTIC TUBING ON HOT WATER OR IN CONTACT WI...

Page 2: ... may be wired from a continuous 115 volt power source Install the on off switch in series with the hot or black wire Install the GA50 Current Sensing Relay in series with the humidistat circuit The Current Sensing Relay will detect furnace operation and supply power to the humidifier accordingly 7 7 5 GFX3 ELECTRONIC HUMIDISTAT Turn on water supply and plug in power cord to check operation of humi...

Page 3: ...d electrical power to humidifier 2 Remove cover water distributor trough evaporator pad pad rails and drain pan Clean excessive mineral deposits from the distributor trough drain pan pad rails and humidifier cabinet A solution of 1 2 vinegar 1 2 water will help loosen mineral deposits Inspect drain hose clean or replace as necessary 3 Replace humidifier evaporator pad if necessary Part number GA19...

Page 4: ...ifier will not operate Humidifier runs without furnace operation or humidifier never shuts off Proper voltage present at solenoid valve 24 VAC but no water flow Too much humidity in home and or condensation on windows 1 Set thermostat to operate both furnace burner and blower Operation may be necessary for system power 2 Humidity level in home may be higher than humidistat setting Increase humidit...

Page 5: ... 16 1 2 ELITE 1000 HUMIDIFIER SPECIFICATIONS Model 1000A GFI 5730 includes Humidifier components GA19 Vapor pad Solenoid Assembly Relay Circuit Board Fan Motor Fan Blades Accessories GFX3 Automatic Digital Humidistat Code Valve Saddle Valve Model 1000M GFI 5735 includes Humidifier Components GA19 Vapor Pad Solenoid Assembly Relay Circuit Board Fan Motor Fan Blades Accessories Manual Humidistat Sad...

Page 6: ...____________________________________________________________ Address ____________________________________________________________________ Address 2 ___________________________________________________________________ City _____________________ State ___________ Zip Code _______________________ Contractor Phone ____________________________________________________________ Contractor Email ___________...

Page 7: ... tuyau d un diam ext de 6 mm 1 4 po au robinet vanne à étrier Les tuyaux en cuivre exigent un écrou à compression et un manchon en laiton Les tuyaux en plastique exigent un insert en laiton à l intérieur des tuyaux ainsi qu une virole en plastique et un écrou en laiton REMARQUE NE PAS UTILISER DE TUYAUX EN PLASTIQUE AVEC DE L EAU CHAUDE OU SUR UNE SURFACE DE CONTACT CHAUDE DE PLÉNUM OU DE CONDUIT ...

Page 8: ...a le fonctionnement de l appareil de chauffage et fournira l alimentation électrique nécessaire à l humidificateur 5 HUMIDISTAT ÉLECTRONIQUE GFX3 Ouvrir l alimentation en eau et brancher le cordon d alimentation pour vérifier le fonctionnement de l humidificateur Régler l humidistat en mode de demande Lorsque l appareil de chauffage est éteint la vanne électromagnétique doit être fermée et le vent...

Page 9: ...tributeur du bac de récupération des rails du tampon et du boîtier de l humidificateur Une solution moitié vinaigre moitié eau aide à déloger les dépôts de minéraux Inspecter le tuyau de l égouttoir le nettoyer ou le remplacer au besoin 3 Remplacer le tampon d évaporation de l humidificateur si nécessaire réf GA19 Installer la goulotte les rails de tampon et le bac de récupération Remettre en plac...

Page 10: ...tique est bonne 24 V c a mais l eau ne coule pas Taux d humidité trop élevé dans la maison ou présence de condensation sur les fenêtres 1 Régler le thermostat de manière à faire fonctionner l appareil de chauffage et le ventilateur il peut être nécessaire que ces appareils fonctionnent pour alimenter le système 2 Le niveau d humidité de la maison peut être plus élevé que le réglage de l humidistat...

Page 11: ...n mètres carrés pieds carrés et le type de construction ACCESSOIRES DES COMPOSANTS DE L HUMIDIFICATEUR EMBALLÉ Cadre de l humidificateur avec la découpe du plénum illustrée en lignes pointillées 30 8 cm 12 1 8 po 35 9 cm 14 1 8 po Nº de modèle Faible 0 75 CAH GPD Moyen 0 50 CAH Élevé 0 30 CAH Elite 570 12 74 m2 800 pi2 111 m2 1200 pi2 186 m2 2000 pi2 Elite 900 17 104 m2 1115 pi2 153 m2 1650 pi2 26...

Page 12: ..._________________________ Adresse __________________________________________________________________ Adresse 2 ________________________________________________________________ Ville ____________________ État Province _____________ Code postal _________ Téléphone ________________________________________________________________ Courriel _______________________________________________________________...

Reviews: