-15-
※
At least once per year, clean pump system
Basic-
1. Press the pump button (P) to drain water from reservoir.
2. Disconnect power to dehumidifier.
3. Mix a 16 oz solution of either 1 oz bleach to 15 oz water or 4 oz white vinegar to 12
oz water. Pour into the drain tray at the base of the coils.
Note: If you get any cleaning solution on the coils, flush with water.
4. Allow to soak for 15 minutes.
5. Reconnect power to dehumidifier.
6. Fill reservoir and flush/cycle pump at least two times with clean water.
7. Repeat if needed or refer to Advanced instructions.
Advanced-
1. a. Use manual pump button“P”, to drain water from reservoir.
b. Unplug the dehumidifier and open cover to access pump.
c. Pump head can be removed from reservoir by pressing on tabs.
d. A wet-dry vacuum or towels can be used to remove remaining water from
reservoir.
2. Fill pump reservoir with a diluted cleaning solution (15 oz water to 1 oz bleach or 12
oz water to 4 oz white vinegar).
3. Reassemble pump and use manual pump button to flush mixtur e through discharge
tubing.
4. Pour same diluted mixture slowly into drain pan under evaporator coil and allow it
to clean hose from pan to pump. This process can be stopped when the pump energizes 1
time.
Note: If you get any bleach/water mixture on coils, flush with water.
5. Pour sufficient clean water through drain pan to force pump to activate twice.
6. Reassemble unit and return it to operational status.
Coil-
If necessary, clean your coils with a vacuum or approved coil cleaner.
-14-
2. Water Pump Maintenance
The pump is designed with quick connection construction. If service is required,
condensate tube, float switch connections, and the main power cord to pump can easily be
disconnected. The pump can be removed from reservoir by using a flat screwdriver to
gently pry pump assembly from reservoir.
Your
WhiteWing SuperDry is equipped with an integral condensate pump designed to
pump condensate from your dehumidifier out to the desired drain. This pump requires
routine maintenance that is not cover ed by your 1 year parts warranty. Only a defective
pump will be repaired or replaced during the warranty period.
Preventative Maintenance
As with all pumps, preventative maintenance is necessary to prevent issues from dirt
and slime that may accumulate in the drain system – including the drain pan, hose to the
condensate pump, pump reservoir, pump head and float assembly, and discharge tubing.