background image

DEHUMIDIFIERS

DEHUMIDIFIERS

SuperDry 90

※ 

Front View

Handle

Wheel

Front cover

Air inlet

Secured Access 

Latch

Air Filter

-3-

Unit Overview

Control panel

Power Cord Input

Hose and

 Cord Rack

Drain Tube

 Connection

Air outlet

※ 

Rear View

 

-2-

How Your SuperDry Dehumidifier Works

The WhiteWing SuperDry Series Dehumidifier utilizes either its integral humidistat to 

monitor the conditioned space or a manual on/off control to energize the compressor 

when needed. Air is drawn across an evaporator coil.  The evaporator coil is cooler than the 

dew point of the air so water vapor will turn into liquid condensation.  Air is then reheated 

through the condenser coil and distributed back into the room.  

Installation:

240 Volts AC may cause serious injury from electric shock.

WARNING!

1. Disconnect electrical power before servicing

2. Only plug unit into grounded electrical outlet 

3. Do not use extension cord

4. Do not use plug adapter

Power Supply:         

115V, 60 Hz AC Only 1 Phase

Outlet Requirement:     3-Prong, GFI

Circuit Protector:           15 Amp Time Delay Fuse or Circuit Breaker

Alternatively, you can manually control unit to operate independent of space conditions.

Place unit in desired location. The inlet of unit should be at least 8”from any 

obstructions.  If unit is transported in the horizontal position, allow it to sit in upright 

position for at least 30 minutes before operating.

It is recommended that the unit be removed from any location where corrosive or high 

VOC content materials are applied.

WARNING!

Summary of Contents for SuperDry 90

Page 1: ...Installation and Operations Manual WhiteWing Dehumidifiers SuperDry 90 DEHUMIDIFIERS P 888 236 7231 Add 300 E Valley Drive Bristol VA 24201...

Page 2: ...dry thoroughly before reconnecting to electric and restarting For proper operation neither the inlet nor discharge should be positioned against a wall A minimum of 12 clearance between unit and any o...

Page 3: ...ions SuperDry 90 Identification 1 Contact your installing contractor Phone SuperDry Dehumidifiers 888 236 7231 Customer Service For additional questions concerning the operation of your dehumidifier F...

Page 4: ...ser coil and distributed back into the room Installation 240 Volts AC may cause serious injury from electric shock WARNING 1 Disconnect electrical power before servicing 2 Only plug unit into grounded...

Page 5: ...basis I n l e t 3 2 7 6 The contents of the second line alternate every 10 sec Operating instructions OK M P Menu Up Button Down Button LCD Monitor On Off Select OK Drain Pump Control Panel Operation...

Page 6: ...The cursor automatically move to R which will be flashing Press OK to confirm move to previous menu or wait 10 seconds and you will automatically return to the main menu 6 The contents of the second...

Page 7: ...rs Note You are selecting on and off periods of time not set clock times d Press the menu key to move the cursor to the on offor off on flashes e Press to confirm key The on off status of C and F will...

Page 8: ...Diameter for supply ducting is 6 Flex or layflat ducting can be used for this purpose 9 Optional Duct Installation SuperDry 90 Preparing the Unit for Use 1 Position the machine for a minimum 8 clearan...

Page 9: ...cks 12 1 Pull up on the handle to release and gently pull out on filter assembly 2 Remove the filter SuperDry 90 b Filter may be cleaned by vacuuming or by washing with warm water no soap or solvents...

Page 10: ...r coil and allow it to clean hose from pan to pump This process can be stopped when the pump energizes 1 time Note If you get any bleach water mixture on coils flush with water 5 Pour sufficient clean...

Page 11: ...d in transit or when handling has been subject to misuse corr osion chemicals acts of God has not been installed operated or serviced according to the Seller s instructions or has been operated beyond...

Page 12: ...nty neglect or otherwise THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS...

Reviews: