background image

DEHUMIDIFIERS

DEHUMIDIFIERS

-11-

The quick connector into 

the socket on the connector

Quick connection to draining tube

( 4 ) Set unit control as desired and energize.

3 ) Firmly insert power cord into socket on top back of unit.

SuperDry  90

Maintenance and Repair

1. Exterior Cleaning

Use a soft, slightly damp cloth to wipe the plastic body.

a. Remove the inlet grille to access the filter

2. Filter cleaning

18’prior to reaching final drain location.

-10-

Ducting of the unit allows conditioning of an adjacent room or focusing discharge in 

an area needing focused attention.  Diameter for supply ducting is 6”. Flex or layflat 

ducting can be used for this purpose.

9.Optional Duct Installation

SuperDry  90

Preparing the Unit for Use

( 1 )  Position the machine for a minimum  8”clearance on front and sides. Rear of 

machine should be positioned for maximum discharge distance or directly towards a 

specific location for spot drying.

If the unit was moved in such a manner that the compressor didn’

t remain in a 

vertical  orientation, wait a minimum of 30 minutes before turning the unit“on.”

( 2 ) The included drain line attaches to the unit via a quick connection type fitting 

located on the base of the unit.The drain line should be routed to a suitable drain or 

outside.  Because the unit features an integral drain pump, drain line may go vertically up 

Summary of Contents for SuperDry 90

Page 1: ...Installation and Operations Manual WhiteWing Dehumidifiers SuperDry 90 DEHUMIDIFIERS P 888 236 7231 Add 300 E Valley Drive Bristol VA 24201...

Page 2: ...dry thoroughly before reconnecting to electric and restarting For proper operation neither the inlet nor discharge should be positioned against a wall A minimum of 12 clearance between unit and any o...

Page 3: ...ions SuperDry 90 Identification 1 Contact your installing contractor Phone SuperDry Dehumidifiers 888 236 7231 Customer Service For additional questions concerning the operation of your dehumidifier F...

Page 4: ...ser coil and distributed back into the room Installation 240 Volts AC may cause serious injury from electric shock WARNING 1 Disconnect electrical power before servicing 2 Only plug unit into grounded...

Page 5: ...basis I n l e t 3 2 7 6 The contents of the second line alternate every 10 sec Operating instructions OK M P Menu Up Button Down Button LCD Monitor On Off Select OK Drain Pump Control Panel Operation...

Page 6: ...The cursor automatically move to R which will be flashing Press OK to confirm move to previous menu or wait 10 seconds and you will automatically return to the main menu 6 The contents of the second...

Page 7: ...rs Note You are selecting on and off periods of time not set clock times d Press the menu key to move the cursor to the on offor off on flashes e Press to confirm key The on off status of C and F will...

Page 8: ...Diameter for supply ducting is 6 Flex or layflat ducting can be used for this purpose 9 Optional Duct Installation SuperDry 90 Preparing the Unit for Use 1 Position the machine for a minimum 8 clearan...

Page 9: ...cks 12 1 Pull up on the handle to release and gently pull out on filter assembly 2 Remove the filter SuperDry 90 b Filter may be cleaned by vacuuming or by washing with warm water no soap or solvents...

Page 10: ...r coil and allow it to clean hose from pan to pump This process can be stopped when the pump energizes 1 time Note If you get any bleach water mixture on coils flush with water 5 Pour sufficient clean...

Page 11: ...d in transit or when handling has been subject to misuse corr osion chemicals acts of God has not been installed operated or serviced according to the Seller s instructions or has been operated beyond...

Page 12: ...nty neglect or otherwise THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS...