TEST THE UNIT PRIOR TO INSTALLATION
To prepare it for testing before installation in wall:
•
Unit needs to be in the upright position for 24 hours before starting.
•
Remove unit from box
•
Plug in unit to electrical outlet
•
Plug in bottle probe
•
Turn on to test (see #4 on the Quick Start Guide for details).
•
Turn off after test
•
Remove Bottle Probe
Electrical Needs
The WhisperKOOL InCellar Unit requires a dedicated 115-volt 20-amp circuit
. The unit draws a large amount of
amps at initial start up. By designating a dedicated circuit breaker, you will guarantee the unit has enough power to
run effectively. Contact an electrician for assistance with the installation of this dedicated electrical circuit:
•
Match the electrical outlet to the plug provided on the WhisperKOOL unit.
•
Provide a dedicated circuit and wiring for the unit.
Plug your WhisperKOOL unit into a surge protector or power conditioner. As with any sensitive electrical equipment,
the WhisperKOOL electrical equipment may be damaged by power surges and spikes. Power surges and spikes are
not covered under warranty.
WE RECOMMEND THAT YOU DO NOT USE A GROUND FAULT INTERRUPTER (GFI) WITH THIS PRODUCT.
Electrical Inlet
The unit is equipped with a power inlet which is located on the right side of the cooling unit and is labeled in the
Quick Reference Guide on page 2. The power inlet is to be connected inside of the cellar.
In case the unit should lose power, check the home/main circuit breaker. If the unit does not respond properly, refer
to the Troubleshooting section.