24 VDC - 3000 VA | 24 VDC - 2000 VA | 230 VAC - 50 Hz
E n j o y G r e e n E n e r g y
Inverter/ Charger
Supreme Combi
whisperpower.com
User Manual
Page 1: ...24 VDC 3000 VA 24 VDC 2000 VA 230 VAC 50 Hz Enjoy Green Energy Inverter Charger Supreme Combi whisperpower com User Manual ...
Page 2: ......
Page 3: ...WhisperPower Inverter Battery Charger Inverter Charger 230V Series 24V 2000W 40A 61242040 24V 3000W 50A 61243050 User Manual Manual edition 2022 02 04 ...
Page 4: ...or errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your Whisper Power Sinewave Inverter Charger Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Model Numbe...
Page 5: ...ervicing the battery connected to the inverter Wear eye protection and gloves Avoid touching your eyes while using this unit Keep fresh water and soap on hand in the event battery acid comes in contact with eyes If this occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention Batteries produce explosive gases DO NOT smoke or have an open spark or fire ne...
Page 6: ...e FCC Rules for 120V models and comply with the CE EMC Standard on 230V models These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there...
Page 7: ... Inverter Battery Charger 7 TABLE OF CONTENTS 1 INTRODUCTION 8 2 PRODUCT DESCRIPTION 8 3 UNDERSTANDING THE UNIT 9 4 INSTALLING THE UNIT 14 5 UNIT OPERATION 17 6 TROUBLESHOOTING 29 7 SPECIFICATIONS 30 8 WARRANTY 32 ...
Page 8: ...multi stage battery charger will charge different types of batteries The built in transfer switch will automatically switch the load to the battery power when the utility power is interrupted This manual will explain how to use this unit safely and effectively Please read and follow these instructions and precautions carefully 2 PRODUCT DESCRIPTION The Sinewave Inverter Charger includes the items ...
Page 9: ...e to follow these instructions can damage the unit and could also result in personal injury or loss of life CAUTION Before beginning unit installation please consider the following The unit should be used or stored in an indoor area away from direct sunlight heat moisture or conductive contaminants When placing the unit allow a minimum of 7 5cm three inches of space around it for optimal ventilati...
Page 10: ...he inverter has to provide AC power to the loads based on Amps x hour energy consumption It is recommended to purchase as much battery capacity as possible AC Load Estimated run time on 24V Battery bank on 24V Input Models 24V 60AH 24V 120AH 50 W 22 hrs 44 hrs 100 W 11 5 hrs 23 hrs 200 W 5 hrs 11 hrs 500 W 2 hrs 4 hrs 1000 W 49 mins 2 hrs 1500 W 27 mins 1 hr 2000 W 15 mins 49 mins 2500 W N R 37 mi...
Page 11: ...epair service when not in use or when troubleshooting It could also be an A B A B OFF type switch to select either one of the two or both paralleling battery banks if available D DC Input Cable All DC Input Wires should be insulated multi strand low resistance wires The DC wires must be copper and with minimum 105o rating Model Thinnest DC Input Wires Gauge Used 1 5 m 5 feet Recommended 2 25 m 7 5...
Page 12: ...r manual AC source selector switch can be used to switch between the multiple sources of shore power to the unit Usually the AC Main Panel includes a main circuit breaker that serves as over current protection and as a disconnect for the AC shore power supply line Additional AC circuit breakers serve individual circuits and one of the AC circuit breakers will serve the unit During By Pass mode the...
Page 13: ...Function Display The display is used to provide unit information and for unit setting L BTS Port The port is used for connecting to the optional Battery Temperature Sensor The thermistor installed inside the ring terminal is used to measure the battery terminal temperature and the unit will make compensation on battery charging voltage for battery charging M Digital Input Port Program Port Can BUS...
Page 14: ...ter the performance Mounting the Unit Choose an appropriate mounting location The unit can be mounted in any direction Use the mounting template below to mark the positions of the mounting screws Drill the 4 mounting holes and place the unit in position and fasten the unit to the mounting surface DC Input Connection WARNING Electrical Shock Hazard The unit On Off switch does not disconnect the DC ...
Page 15: ...icle chassis or a dedicated DC ground bus For Marine the common ground point is usually the DC ground bus or engine negative bus Note Do not use the Chassis DC Ground Lug for your AC Grounding For AC Grounding see AC Wiring instructions for more details AC Input and AC Output Hardwire Connections WARNING Before making any AC Input and AC Output Hardwire connection please be sure the AC Input Sourc...
Page 16: ...USA and elsewhere demand this Neutral to Ground bonding If RCD GFCI is not required for your installation the Ground Screw can be removed and this will un bond the AC output neutral pin of the inverter section to the unit s chassis Note This Ground Screw either in used or not will not have any effect between unit s AC Input Neutral and chassis Multi Function Display Connection Route the RJ12 cable...
Page 17: ... Output Switch is turned ON and AC is available at the Output Socket OFF AC Output Switch is turned OFF and AC is not available at the Output Socket Status Green AC Output is running from Utility Green Flash AC Output is running from utility and battery charger is charging the battery Amber AC Output is running from Inverter Amber Flash Utility is detected and is under verification AC Output is st...
Page 18: ...utton once to view unit setting as listed on the Unit Setting Function Chart The or button can be used to scroll through each unit setting If a particular setting needs to be modified press and hold the Menu Set button for 5 seconds and the set parameter will flash on the display Use the or button to scroll through the available settings Once the desired setting is chosen press and hold the Menu S...
Page 19: ...rging when AC Input is available Battery Type Default GEL Battery default Bulk Charge Float Voltage is 28 4V 27 6V AGM Battery default Bulk Charge Float Voltage is 28 6V 26 8V Flooded Battery default Bulk Charge Float Voltage is 28 8V 27 0V Lithium Battery default Bulk Charge Float Voltage is 27 8V 27 0V Program default Bulk Charge Float Voltage is 27 6V 26 4V Power Supply Mode Default Power Suppl...
Page 20: ...rce AC Output power is running from AC Input Source AC Output is available at both the AC Output socket and the AC Output Hardwire terminal if AC Output switch is turned On indicated by AC Output indicator located on the left side of the Display and also the Main unit being On Note Press and hold the Escape button on the Display panel for 5 seconds to toggle AC Output switch On Off Solid AC Input ...
Page 21: ... and the battery is 27 0V Second bottom bar flashing indicates the battery is in Bulk charging stage and the battery is 25 0V Bottom bar flashing indicates the battery is in Bulk charging stage and the battery is 23 0V No bar indicates the battery is in Bulk charging stage and the battery is 21 0V Battery icon flashing indicates the battery is in Bulk charging stage and the battery is below 21 0V ...
Page 22: ... Inverter only b Load Sense Function Load Sense Mode This Load Sense function is only effective when the unit is running as inverter Battery power mode Off Unit provides continuous AC Output power all the time 10 Load Sense power setting is set to 10W Unit will provide continuous AC Output only when the AC load connected to the AC Output is 10W AC Output will switch back to pulsing AC Output every...
Page 23: ...arm Voltage must be with a minimum of 1 0V above the Battery Low Disconnect BLd Voltage and must be with a minimum of 1 0V below the Battery Low Recovery bLr Voltage Battery Under Voltage Recovery Selectable range 23 0 26 0V 0 2V step Default 24 0V The Battery Low Recovery Voltage must be with a minimum of 1 0V above the Battery Low Alarm bLA Voltage Battery Over Voltage Disconnect 33 0 V Not User...
Page 24: ... 6 29 6V 27 6V 26 0 28 0 26 4V 25 6 28 0 25 6V Power Supply 26 0 28 0V 27 6V Consult the battery manufacturer when choosing the bulk and float voltage for the battery bank When selecting the Float voltage it has to be with a minimum of 0 8V below Bulk Voltage setting The Recharged Voltage determines the restart cycle of the battery bank The charger will go through a full recharge cycle when the ba...
Page 25: ...e setting Setting to Low temperature will compensate the charging voltage by 1 35 on GEL and Flooded battery type and 1 05V on AGM battery type Setting to Nor will have no change to the selected charging voltage Setting to HI temperature will compensate the charging voltage by 0 54V on GEL and Flooded battery type and 0 42V on AGM battery type Optional Battery Temperature Sensor BTS Installed If t...
Page 26: ...the Digital Input port Battery charging must be reduced when output power demand exceeds the current limit set for the circuit breaker on the input source to prevent this external breaker from tripping Independent current limiting settings can be programmed for normal shore AC input and for generator The limiting value for Generator input may be programmed and applied GPW by activating the Digital...
Page 27: ... inverter has shutdown Check battery voltage or determine if any external charger is connected to the battery bank that leads to high battery voltage E03 When unit is in Battery Inverter mode AC output is overloaded or short circuited and inverter has shutdown Check load connected to the output Reduce load and restart the unit Note E03 will shows for about 30 seconds After 30 seconds Display will ...
Page 28: ...d AC Output wiring E16 Internal Fault Unit damage Consult Customer Service for assistance E17 AC Input Current withdrawn from the unit is close to the set AC Circuit Breaker Cbr rating Reduce AC load Check the AC Circuit Breaker Cbr rating match with the external AC Input Source Branch Breaker rating E18 AC Input Current drawn by unit is beyond the current rating of the transfer switch 30A for 120...
Page 29: ...ed DC over voltage under voltage or other shutdown type errors in addition to overload Check battery voltage For 120V model GFCI may have tripped Reset GFCI Charger did not supply charging current Check charger setting Charger may be set to Off Set Charger function CHG to On Unit had determined the battery is bad See also description in Error Code E01 By Pass Mode and E11 Check battery and remove ...
Page 30: ...DC DC Input Voltage operating range 21 0 33 0 VDC Under Voltage Alarm 22 0 25 0 VDC Under Voltage Alarm Recovery 23 0 26 0 VDC Under Voltage Shutdown 21 0 24 0 VDC Under Voltage Recovery 23 0 26 0 VDC Over Voltage Shutdown Recovery 33 0 32 0 VDC AC Transfer Switch Transfer Time 30 ms Transfer Relay Rating 16A AC Input Source Setting 4 6 8 10 12 13 14 16A AC Output Hardwire max 16A AC Output Socket...
Page 31: ...vironmental 230VAC Series Conformance LVD EN IEC 62040 1 IEC 61558 2 16 EMI EMC EMC EN IEC 62040 2 Category C1 Agency Markings CE Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Relative Humidity 5 90 non condensing Operating Altitude Up to 3000m 9 843ft above sea level Weights and Dimensions Weights 2000W Series 8 0 kg 17 6 lbs Weights 3000W Series 30...
Page 32: ...fer to the Whisper Power general conditions of sales 8 1 Exclusion of warranty No warranty claims will be accepted for damage resulting from handling usage or processing that does not explicitly appear in this manual Cases of damage arising from the following causes are notably excluded from the warranty Surge voltage on the battery input for example 48 V on the battery input of an WP INVERTER CHA...
Page 33: ...fore returning product to retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of orig inal purchase Any defective unit that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a unit is returned more than 30 days...
Page 34: ...34 WhisperPower Inverter Battery Charger ...
Page 35: ...WhisperPower Inverter Battery Charger 35 ...
Page 36: ...Enjoy Green Energy WhisperPower BV Kelvinlaan 82 9207 JB Drachten The Netherlands www whisperpower com sales whisperpower com ...