Thermistor and Possible Frost Build-Up
Correction:
There are multiple potential causes for the concern.
Therefore be sure to read and follow all instructions. Also have
the Service Manual on hand for any instructions.
https://tinyurl.
com/ybeuyvfy
Diagnostic and Replacement
1.
It is very important to enter the diagnostics program and
confirm the control is the proper version. Proceed to test
128 to read the current version. See chart below for the
appropriate software version. Control does not have to be
replaced if version code correct.
KRFC604F*
Service Step 128: 7.0.0
or higher is required
WRF992FIF*
Service Step 128: 7.0.0
or higher is required
KRFC704F*
Service Step 128: 7.0.0
or higher is required
WRF993FIF*
Service Step 128: 7.0.0
or higher is required
JFFCC72EF*
Service Step 128: 70.0
or higher is required
WRF995FIF*
Service Step 128: 7.0.0
or higher is required
When you order the following part number, If the part number
changes it will be substituting to the newest part.
Model
Control Board
Board Location
KRFC604F*
W11332011 Rev A
Back left of unit (middle)
KRFC704F*
W11332011 Rev A
Back left of unit (middle)
JFFCC72EF*
W11332011 Rev A
Back left of unit (middle)
WRF992FIF*
W10687089 Rev J
Back left of unit (middle)
WRF993FIF*
W10687089 Rev J
Back left of unit (middle)
WRF995FIF*
W10687089 Rev J
Back left of unit (middle)
The location of the board shown on the pictures below (GF2 high
voltage board).
2.
Remove the RC Evaporator cover to verify the gasket type
is the correct version. The correct version should seal all of
the gaps preventing any air leaks. Leaks will cause moist air
to bypass the evaporator and accumulate frost. If the RC
evaporator cover is not the correct version, replace using the
table below.
NOTE:
Before you can remove the evaporator cover the doors
need to be removed.
Door removal and replace Video Link:
https://tinyurl.com/
y8xcv9tm
Door removal and replace Training Pointer Link:
Photos of older version of thinner gasket are given below:
Before reassembly, check new evaporator cover make sure seals
are not damaged or out of place. See photo below for proper
seal placement.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
GF2 Board