Service Competence Center
Ind
u
ctio
n
G
0
Service
Code
Type
Repair suggestions:
shown on
display
Failure description
of failure
Points to check subsequently until the appliance starts to work properly
again.
Failure description / repair
Troubleshooting
C-81
(NTCs ) Board or
Heatsink
over-temperature
Type 2
Check the cooktop installation
Check if customer is using wrong diameter size pan/pot
C-82
Coil Over Temperature
Type 1 1)
Check the cooktop installation
Check if customer is using wrong diameter size pan/pot
C-83
Coil NTC Stuck
Type 1 1)
Check the cooktop installation
2)
Replace interested Coil
3)
Replace power unit
C-84
Main line shape error
Type 2 1)
Check the frequency of the phase connected to the IPC. If the frequency is not
(50
±
2 ) Hz then the cause of the failure is not due to the appliance.
2)
If frequency is OK, then replace the power unit board
C-85
Bad Curve
Type 2
Change Pan or brand
Note:
For failure numbers that are bigger than 80; the letter that is shown is a “C” instead of “F”.
Summary of Contents for G0
Page 1: ... Service Competence Center Induction G0 Induction cooktop G0 ...
Page 8: ... Service Competence Center Installation Installation Induction G0 ...
Page 9: ... Service Competence Center Installation Installation Induction G0 ...
Page 35: ... Service Competence Center Components overview components Induction G0 ...
Page 36: ... Service Competence Center Components overview components Induction G0 ...
Page 39: ... Service Competence Center Components overview cable connections Induction G0 ...
Page 44: ... Service Competence Center Components Zone NTC PTN 312 Induction G0 ...
Page 72: ... Service Competence Center Trouble Shooting Wiring Diagram Induction G0 ...
Page 74: ... Service Competence Center Induction G0 Marketing Range overview ...
Page 75: ... Service Competence Center Induction G0 Marketing Control panel variants ...
Page 79: ... Service Competence Center Documents Induction G0 I F U ...