Type of failure codes
Ind
u
ctio
n
G
0
Failure type 2
usually comes from IPCs ( there could be some
exceptions). These failures affect the whole IPC, in
any case the user may continue to use the burners
that belong to the other IPC. When this type of
failure occurs than USIF becomes insensitive to
subsequent changes of settings on that IPC. If the
user presses the buttons related that IPC that
presents the failure then a Long_beep is emitted.
Every failure type 2 (that concerns one IPC only) is
shown on the displays that are associated to that
IPC. Supposing to have the error coded with F23
for the IPC1, it will be shown intermittently a “F F”,
a “2 3” on those displays.
(See pictures below- Each frame is showed for one
second on the USIF).
F23
Summary of Contents for G0
Page 1: ... Service Competence Center Induction G0 Induction cooktop G0 ...
Page 8: ... Service Competence Center Installation Installation Induction G0 ...
Page 9: ... Service Competence Center Installation Installation Induction G0 ...
Page 35: ... Service Competence Center Components overview components Induction G0 ...
Page 36: ... Service Competence Center Components overview components Induction G0 ...
Page 39: ... Service Competence Center Components overview cable connections Induction G0 ...
Page 44: ... Service Competence Center Components Zone NTC PTN 312 Induction G0 ...
Page 72: ... Service Competence Center Trouble Shooting Wiring Diagram Induction G0 ...
Page 74: ... Service Competence Center Induction G0 Marketing Range overview ...
Page 75: ... Service Competence Center Induction G0 Marketing Control panel variants ...
Page 79: ... Service Competence Center Documents Induction G0 I F U ...