Repair suggestions:
shown on
display
Failure description
of failure
Points to check subsequently until the appliance starts to work properly again.
Troubleshooting
Failure description / repair
F-00
No failure occurred
Type1
1)
One or more keys are pressed permanently for more than 10 sec.(USIF side). The
cause could be liquid, dirty, or objects on the glass, near or on the keys In this
case the USIF will switch OFF the cooktop, setting all level set to zero, but no
Failure will be shown this time (only the acoustic feedback - beep is signalized to
the user now)
F-01
Short on IGBT
Type 2 1)
Replace the power unit board
F-02
DC Link Over voltage
Type 2
1)
Measure the mains voltage& check if it is inside nominal range plus/minus
tolerance
2)
If mains line voltage is OK then replace the power unit board
F-04
DC Link Under voltage
Type 2
1)
Measure the mains voltage& check if it is inside nominal range plus/minus
tolerance
2)
If mains line voltage is OK then replace the power unit board
F-05
Gate Driver fault
Type 1 1)
Replace the power unit board
F-06
Main frequency wrong/
Zero crossing fault
Type 2
1)
Check the frequency of the phase connected to the IPC. If the frequency is not (50
±
2 ) Hz then the cause of the failure is not due to the appliance.
2)
If frequency is OK, then replace the power unit board
F-07
Main relay stuck open
Type 2 1)
Replace the power unit board
F-10
HW fault on Vce
retrigger
Type 2 1)
Replace the power unit board
F-12
Coil Under Current
Type 1
1)
Check if the coil that is showing the failure is well plugged in the proper connector.
2)
Replace the coil with a new one (coil of the same size) .If this does not fix the hob,
then the old coil is still good, so place it back in the appliance.
3)
Change the IPC that has connected that coil
Summary of Contents for G0
Page 1: ... Service Competence Center Induction G0 Induction cooktop G0 ...
Page 8: ... Service Competence Center Installation Installation Induction G0 ...
Page 9: ... Service Competence Center Installation Installation Induction G0 ...
Page 35: ... Service Competence Center Components overview components Induction G0 ...
Page 36: ... Service Competence Center Components overview components Induction G0 ...
Page 39: ... Service Competence Center Components overview cable connections Induction G0 ...
Page 44: ... Service Competence Center Components Zone NTC PTN 312 Induction G0 ...
Page 72: ... Service Competence Center Trouble Shooting Wiring Diagram Induction G0 ...
Page 74: ... Service Competence Center Induction G0 Marketing Range overview ...
Page 75: ... Service Competence Center Induction G0 Marketing Control panel variants ...
Page 79: ... Service Competence Center Documents Induction G0 I F U ...