background image

20" (50.8 CM), 30" (76.2 CM) AND 43" (109.2 CM) 

ELECTRIC DOWNDRAFT COOKTOP INSTALLATION 

INSTRUCTIONS 

INSTRUCTIONS D’INSTALLATION DE LA TABLE DE 

CUISSON ÉLECTRIQUE AVEC ASPIRATION PAR LE BAS DE 

20" (50,8 CM), 30" (76,2 CM) ET 43" (109,2 CM)

COOKTOP SAFETY

W10421939B

Table of Contents/Table des matières

COOKTOP SAFETY ........................................................................1

INSTALLATION REQUIREMENTS ................................................2

Tools and Parts ............................................................................2
Location Requirements ................................................................2
Venting Requirements ..................................................................4
Venting Methods ..........................................................................5
Electrical Requirements  ..............................................................7

INSTALLATION INSTRUCTIONS ..................................................8

Prepare Cooktop ..........................................................................8
Rotate Blower - Optional..............................................................8
Install Cooktop .............................................................................9
Make Electrical Connection .......................................................10
Complete Installation..................................................................11

SÉCURITÉ DE LA TABLE DE CUISSON .................................12

EXIGENCES D'INSTALLATION ................................................12

Outillage et pièces...................................................................12
Exigences d'emplacement......................................................12
Exigences concernant l'évacuation ........................................16
Méthodes d'évacuation...........................................................17
Spécifications électriques .......................................................19

INSTRUCTIONS D’INSTALLATION .........................................20

Préparation de la table de cuisson .........................................20
Rotation du ventilateur – facultative........................................20
Installation de la table de cuisson...........................................21
Raccordement électrique........................................................22
Achever l'installation ...............................................................23

You can be killed or seriously injured if you don't immediately 
 

You

 

can be killed or seriously injured if you don't follow 

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety 
messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”

These words mean:

follow instructions.

instructions.

DANGER

WARNING

IMPORTANT:

 

Save for local electrical inspector's use.

IMPORTANT :

À conserver pour consultation par l'inspecteur local des installations électriques.

Summary of Contents for 20" (50.8 CM)

Page 1: ...cuisson 20 Rotation du ventilateur facultative 20 Installation de la table de cuisson 21 Raccordement lectrique 22 Achever l installation 23 You can be killed or seriously injured if you don t immedi...

Page 2: ...alling a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Use the countertop opening dimensions that are given with these Installation Instructions Given...

Page 3: ...imum performance Minimum clearance of 1 2 5 cm is required to sidewalls and 1 9 cm to rear wall A minimum clearance of 6 15 9 cm is recommended for removal of the grease containers Installed dimension...

Page 4: ...s 43 109 2 cm on 43 109 2 cm triple cartridge models B Combustible area above countertop shown by dashed box above C 30 76 2 cm minimum clearance between top of cooktop platform and bottom of uncovere...

Page 5: ...an cause excess turbulence that reduces airflow Do not use a 5 12 7 cm elbow in a 6 15 2 cm or 3 x 10 8 3 x 25 4 cm system Do not reduce to a 5 12 7 cm system after using 6 15 2 cm or 3 x 10 8 3 x 25...

Page 6: ...7 cm to 15 2 cm transition F 6 15 2 cm round metal duct G 6 15 2 cm round PVC coupling H Concrete slab I 6 15 2 cm round PVC sewer pipe J 6 15 2 cm round 90 PVC sewer pipe elbow K Tightly pack gravel...

Page 7: ...ts If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes Check wit...

Page 8: ...local codes and industry accepted wiring practices INSTALLATION INSTRUCTIONS PrepareCooktop Decide on the final location for the cooktop 1 Open product as instructed on product packaging 2 Remove ship...

Page 9: ...tire cooktop up from the cutout to avoid scratching the countertop 2 Connect blower exhaust scroll to ducting 3 Use vent clamps to secure the ducting to the blower exhaust scroll 4 Use the hold down s...

Page 10: ...TANT Use the 3 wire cable from power supply where local codes permit connecting the frame ground conductor to the neutral white junction box wire 1 Disconnect power 2 Remove wiring box cover from the...

Page 11: ...on of the Use and Care Guide 5 Read Cooktop Use in the cooktop Use and Care Guide 6 Reconnect power 7 Use the Flow Tester Card provided with your cooktop to check the airflow see card for step by step...

Page 12: ...ce doit tre vit Si des placards de rangement sont envisag s le risque peut tre r duit par l installation d une hotte de cuisine d passant le bas des placards d au moins 5 12 7 cm horizontalement Utili...

Page 13: ...ntre la table de cuisson et la paroi lat rale pour une performance maximale Un d gagement minimum de 1 2 5 cm avec les parois lat rales et de 1 9 cm avec le mur arri re Un d gagement minimal de 6 15 9...

Page 14: ...ue de 20 50 8 cm 30 76 2 cm sur les mod les module amovible double de 30 76 2 cm 43 109 2 cm sur les mod les module amovible triple de 43 109 2 cm B Zone de mati re combustible au dessus du plan de tr...

Page 15: ...rale pour un rendement maximal Dimensions de l ouverture d couper A 18 47 5cm 0 2 cm sur les mod les module amovible unique de 20 50 8 cm 30 77 3 cm 0 2 cm sur les mod les module amovible unique de 30...

Page 16: ...duit une paisseur de 30 pour l acier galvanis ou de 26 pour l aluminium si c est permis par les codes locaux Cette information est bas e sur l information dans la Section des Codes R sidentiels Inter...

Page 17: ...le mur A B A B A B A B 3 x 10 8 3 x 25 4 cm A Bouche de d charge murale B 12 30 5 cm minimum C Dalle de b ton D Conduit PVC dia 6 15 2 cm pour gout E Raccord de transition 5 6 12 7 cm 15 2 cm F Condui...

Page 18: ...moteur du ventilateur la volute d vacuation du ventilateur 3 Retirer le moteur du ventilateur B de sa volute d vacuation E 4 Dans l ouverture de la volute d vacuation du ventilateur retirer avec pr ca...

Page 19: ...109 2 cm Le circuit doit tre prot g par fusible chaque extr mit du circuit La table de cuisson doit tre connect e directement au bo tier de connexion par l interm diaire du conduit m tallique flexibl...

Page 20: ...Au d ballage la spirale d chappement du ventilateur est orient e vers l arri re du placard pour une vacuation travers une paroi ext rieure Pour tourner le ventilateur 1 Rep rer les 4 bouchons en plast...

Page 21: ...du ventilateur aux conduits 3 Utiliser des brides de conduit pour fixer les conduits la volute d vacuation du ventilateur 4 Utiliser les brides de fixation fournies dans le paquet de pi ces de quincai...

Page 22: ...de la table de cuisson 4 Connecter le conducteur de terre vert ou nu du point de distribution du domicile au conducteur de terre vert ou nu dans le bo tier de connexion de la chambre de distribution a...

Page 23: ...ation 1 V rifier que toutes les pi ces sont maintenant install es S il reste une pi ce passer en revue les diff rentes tapes pour d couvrir laquelle aurait t oubli e 2 V rifier la pr sence de tous les...

Page 24: ...its r serv s Registered Trademark Trademark of Jenn Air U S A Used under license by Maytag Limited in Canada Marque d pos e Marque de commerce de Jenn Air U S A Emploi sous licence par Maytag Limited...

Reviews: