7

Example vent system

NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce 
performance.

Determine Range Blower Setting

This cooktop is equipped with a dual range blower. It is shipped 
from the factory in the low range for most installations. If the 
equivalent duct length exceeds 30 ft (9.1 m), it must be converted 
to high range. Do not convert the blower to high range for shorter 
lengths; this will cause excessive noise and conditioned air loss. 
Convert blower before installing into countertop if necessary.

To Convert to High Range:

1. Using 2 or more people, place cooktop on floor with front 

edge and plenum down.

2. Remove the four acorn nuts (A) that attach the blower motor 

assembly to the blower exhaust scroll.

3. Remove the blower motor assembly (B) from the blower 

exhaust scroll (E).

4. Slowly reach in the blower exhaust scroll opening and 

remove the snap ring (C).

5. Gently remove the restrictor ring (D).

6. Place the motor assembly back on the studs of the blower 

exhaust scroll.

7. Reattach the four acorn nuts to secure the blower motor 

assembly back to the blower exhaust scroll.

Electrical Requirements 

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.

Check with a qualified electrical installer if you are not sure the 
cooktop is properly grounded.

Make sure that the electrical connection and wire size are 
adequate and in conformance with the National Electrical Code, 
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, 
Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest 
edition, and all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471

CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575

1- 90° elbow

= 5 ft (1.5 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

1 - wall cap

= 0 ft (0 m)

System length

= 13 ft (3.9 m)

90˚ elbow

2 ft 

(0.6 m)

6 ft (1.8 m)

wall cap

WARNING

Excessive Weight Hazard

Use two or more people to move and install cooktop.

Failure to do so can result in back or other injury.

A. Acorn nuts (4)
B. Blower motor assembly

C. Snap ring
D. Restrictor ring

E. Blower exhaust scroll

A

B

C

D

E

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire.

Electrically ground cooktop.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

Summary of Contents for 20" (50.8 CM)

Page 1: ...cuisson 20 Rotation du ventilateur facultative 20 Installation de la table de cuisson 21 Raccordement lectrique 22 Achever l installation 23 You can be killed or seriously injured if you don t immedi...

Page 2: ...alling a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Use the countertop opening dimensions that are given with these Installation Instructions Given...

Page 3: ...imum performance Minimum clearance of 1 2 5 cm is required to sidewalls and 1 9 cm to rear wall A minimum clearance of 6 15 9 cm is recommended for removal of the grease containers Installed dimension...

Page 4: ...s 43 109 2 cm on 43 109 2 cm triple cartridge models B Combustible area above countertop shown by dashed box above C 30 76 2 cm minimum clearance between top of cooktop platform and bottom of uncovere...

Page 5: ...an cause excess turbulence that reduces airflow Do not use a 5 12 7 cm elbow in a 6 15 2 cm or 3 x 10 8 3 x 25 4 cm system Do not reduce to a 5 12 7 cm system after using 6 15 2 cm or 3 x 10 8 3 x 25...

Page 6: ...7 cm to 15 2 cm transition F 6 15 2 cm round metal duct G 6 15 2 cm round PVC coupling H Concrete slab I 6 15 2 cm round PVC sewer pipe J 6 15 2 cm round 90 PVC sewer pipe elbow K Tightly pack gravel...

Page 7: ...ts If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes Check wit...

Page 8: ...local codes and industry accepted wiring practices INSTALLATION INSTRUCTIONS PrepareCooktop Decide on the final location for the cooktop 1 Open product as instructed on product packaging 2 Remove ship...

Page 9: ...tire cooktop up from the cutout to avoid scratching the countertop 2 Connect blower exhaust scroll to ducting 3 Use vent clamps to secure the ducting to the blower exhaust scroll 4 Use the hold down s...

Page 10: ...TANT Use the 3 wire cable from power supply where local codes permit connecting the frame ground conductor to the neutral white junction box wire 1 Disconnect power 2 Remove wiring box cover from the...

Page 11: ...on of the Use and Care Guide 5 Read Cooktop Use in the cooktop Use and Care Guide 6 Reconnect power 7 Use the Flow Tester Card provided with your cooktop to check the airflow see card for step by step...

Page 12: ...ce doit tre vit Si des placards de rangement sont envisag s le risque peut tre r duit par l installation d une hotte de cuisine d passant le bas des placards d au moins 5 12 7 cm horizontalement Utili...

Page 13: ...ntre la table de cuisson et la paroi lat rale pour une performance maximale Un d gagement minimum de 1 2 5 cm avec les parois lat rales et de 1 9 cm avec le mur arri re Un d gagement minimal de 6 15 9...

Page 14: ...ue de 20 50 8 cm 30 76 2 cm sur les mod les module amovible double de 30 76 2 cm 43 109 2 cm sur les mod les module amovible triple de 43 109 2 cm B Zone de mati re combustible au dessus du plan de tr...

Page 15: ...rale pour un rendement maximal Dimensions de l ouverture d couper A 18 47 5cm 0 2 cm sur les mod les module amovible unique de 20 50 8 cm 30 77 3 cm 0 2 cm sur les mod les module amovible unique de 30...

Page 16: ...duit une paisseur de 30 pour l acier galvanis ou de 26 pour l aluminium si c est permis par les codes locaux Cette information est bas e sur l information dans la Section des Codes R sidentiels Inter...

Page 17: ...le mur A B A B A B A B 3 x 10 8 3 x 25 4 cm A Bouche de d charge murale B 12 30 5 cm minimum C Dalle de b ton D Conduit PVC dia 6 15 2 cm pour gout E Raccord de transition 5 6 12 7 cm 15 2 cm F Condui...

Page 18: ...moteur du ventilateur la volute d vacuation du ventilateur 3 Retirer le moteur du ventilateur B de sa volute d vacuation E 4 Dans l ouverture de la volute d vacuation du ventilateur retirer avec pr ca...

Page 19: ...109 2 cm Le circuit doit tre prot g par fusible chaque extr mit du circuit La table de cuisson doit tre connect e directement au bo tier de connexion par l interm diaire du conduit m tallique flexibl...

Page 20: ...Au d ballage la spirale d chappement du ventilateur est orient e vers l arri re du placard pour une vacuation travers une paroi ext rieure Pour tourner le ventilateur 1 Rep rer les 4 bouchons en plast...

Page 21: ...du ventilateur aux conduits 3 Utiliser des brides de conduit pour fixer les conduits la volute d vacuation du ventilateur 4 Utiliser les brides de fixation fournies dans le paquet de pi ces de quincai...

Page 22: ...de la table de cuisson 4 Connecter le conducteur de terre vert ou nu du point de distribution du domicile au conducteur de terre vert ou nu dans le bo tier de connexion de la chambre de distribution a...

Page 23: ...ation 1 V rifier que toutes les pi ces sont maintenant install es S il reste une pi ce passer en revue les diff rentes tapes pour d couvrir laquelle aurait t oubli e 2 V rifier la pr sence de tous les...

Page 24: ...its r serv s Registered Trademark Trademark of Jenn Air U S A Used under license by Maytag Limited in Canada Marque d pos e Marque de commerce de Jenn Air U S A Emploi sous licence par Maytag Limited...

Reviews: