3-16
Electrical Shock Hazard
Connect green ground wires to ground
screws.
Failure to do so can result in death or
electrical shock.
Perform the following steps to reinstall the
evaporator.
1.
Mount the new evaporator to the unit with
its two front and two side screws, and then
braze the joints.
2.
Place a strip of foam tape along the top of
the evaporator.
3.
Install the two upper styrofoam air shields
over the evaporator.
5.
Mount the top air guide to the unit with its
eight screws.
6.
Mount the brace with its four screws.
7.
Mount the control housing to the unit with
its three screws.
8.
Mount the control assembly to the hous-
ing.
9.
Mount the two green ground wires to the
evaporator with their hex-head screws.
4.
Make sure that the rubber wire block is
positioned in its cutout so that there are no
air leaks around it.
Keep
Seal
Tight
12. Braze on an access valve and discharge
the refrigerant into an approved recovery
system.
13 . Unbraze the two joints from the evapora-
tor and remove the evaporator.
Evaporator
Joints