K/iK Series AC Servo Driver
164
Parame
ter No.
Name
Setting range
Setting unit
Factory setting
Power
reboot
Remarks
P□648
Step change condition value 2 in
data set 12
0 ~ 65535
——
0
Y
Ditto
P□649
Follow-up data set number of data
set 12
0 ~ 14
——
13
Y
P□650
Type of data set 13
0 ~ 2
——
0
Y
0: data set is null
1: data set is in absolute motion
2: data set is in relative motion
P□651
Low byte value of Data Set 13
-9999~+9999
1-reference pulse
0
Y
P□652
High byte value of Data Set 13
-9999~+9999
10000-reference
pulse
0
Y
P□653
Speed of data set 13
0 ~ 6000
rpm
100
Y
P□654
Step change attribute in Data Set
13
——
——
0000
Y
P□655
Step change condition value 1 in
data set 13
0 ~ 65535
——
0
Y
- Unconditional: no transitional condition value
- Delay: value 0 ~ 65535: latency time0 ~ 65535, unit: ms
- Pulse edge required for step change:
Value 0: rising edge