C O N T R O L P A N E L
page 3 – 6
D-9 / Oct 2003
Solo (AFL)/Mute/Dim/Cue (PFL) Section
The PFL(CUE) master level control and
defeat switch are located on the top section
of the EFS panel. The PFL/CUE signal is
pre-fader, and is normally used to check
signals. When a channel is CUEd, its pre-
fader signal will appear in the external cue
speaker, and the switched meter array in the
master LCD display will show the level of
the pre-fader signal.
The PFL(CUE) level control determines the overall loudness of the
cue signal.
Similar to the control room speakers, the external cue speaker also
has the potential for feedback and should be muted (using the configu-
ration software—VDIP menu) whenever the control room speakers are.
The PFL DEFEAT switch allows for temporarily overriding, or cancel-
ling, the mute function.
The AFL(SOLO) master level control and defeat switch are also
located on the top section of the EFS panel. The AFL/SOLO signal is
after fader, and is normally used to check a mix. When an output (such
as an AUX SEND) is SOLOed, its post-fader signal will appear in the
solo output (and usually, the control room speakers). The switched
meter array in the master LCD display will show the level of the mix.
The solo defeat switch allows for disabling the control room solo
interrupt function.
The DIM master level control and defeat switch are also located on
the top of the EFS panel. The DIM level control sets the amount of
attenuation applied to a monitor signal (such as control room output)
when its DIM switch is engaged, and also sets the level of the normal
feed when it is interrupted by the TB signal. The dim defeat switch
allows for temporarily overriding the attenuation to bring all DIMmed
signals back to their normal level.
D-9 / Jan 2007
Summary of Contents for D-9
Page 63: ...D 9 May 2005 page 7 2 ...
Page 64: ...D 9 May 2005 page 7 3 ...
Page 65: ...D 9 May 2005 page 7 4 ...
Page 66: ...D 9 May 2005 page 7 5 ...
Page 67: ...page 7 6 D 9 May 2005 ...
Page 68: ...D 9 May 2005 page 7 7 ...
Page 69: ...page 7 8 IP 9 4 Inputs Panel Switch Card Load Sheet D 9 May 2005 ...
Page 70: ...page 7 9 D 9 Oct 2003 ...
Page 71: ...page 7 2 D 9 Oct 2003 S C H E M A T I C D R A W I N G S IQ 9 IQ Card Load Sheet page 7 10 ...
Page 72: ...page 7 11 D 9 Oct 2003 ...
Page 73: ...page 7 12 D 9 Oct 2003 ...
Page 74: ...page 7 13 D 9 Oct 2003 ...
Page 75: ...page 7 14 D 9 Oct 2003 ...
Page 76: ...page 7 15 D 9 Oct 2003 ...
Page 77: ...page 7 16 MN 9 Control Panel Switch Card Load Sheet D 9 Oct 2003 ...
Page 78: ...D 9 May 2005 page 7 17 ...
Page 79: ...D 9 May 2005 page 7 18 ...
Page 80: ...page 7 19 MFS 9 4 Master Panel Switch Card Load Sheet D 9 May 2005 ...
Page 84: ...D 9 Oct 2003 page 7 23 ...
Page 85: ...D 9 Oct 2003 page 7 24 ...
Page 86: ...D 9 Oct 2003 page 7 25 ...
Page 87: ...page 7 26 DCM 9 DCM Panel Switch Card Load Sheet D 9 Oct 2003 ...
Page 95: ...page 7 34 HC 9 Host Controller Card Load Sheet D 9 Apr 2008 ...
Page 96: ...page 7 35 D 9 Oct 2003 ...
Page 97: ...page 7 36 BP 9 Back Plane Card Load Sheet D 9 Oct 2003 ...
Page 98: ...page 7 37 D 9 Oct 2003 ...
Page 100: ...D 9 Oct 2003 page 7 39 ...
Page 102: ...D 9 Oct 2003 page 7 41 ...
Page 104: ...page 7 43 D 9 Oct 2003 ...
Page 106: ...page 7 45 D 9 Oct 2003 ...