Part Number:
350092
Issue: 3
Page 37 of 125
© Copyright Westomatic Vending Services Limited 2020
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by
any means, electrical, mechanical, photocopying, recording or otherwise, without prior permission from Westomatic Vending
Services Limited.
12.10
►
One button flush
It is possible to flush the machine without entering the
operational menus. The flush buttons are located on the VMC
cover on the inside of the door, these buttons will flush juices
1, 2 and 3 where fitted. The other button will flush the chiller
unit and the water and UV filters.
Note juice flush buttons are push and hold.
Changes to the amount of water or juice to be flushed can be
altered in the flush setting menu, see below.
► SERVICE MODE <Enter Access Code>
└►
MACHINE SETTINGS
└►
FLUSH & CLEAN
└►
Still water
← Still water throw in seconds
└►
Juice
← Syrup throw time in seconds
Remove the bag in box connector by half turning anticlockwise and pull off towards you, insert
a relief valve into the connector, and immerse in a bucket of clean warm water.
For instructions on how to sterilise the juice lines & Chiller
see section
Error! Reference source
not found.
.