background image

Congratulations

 

on

 

the

 

purchase

 

of

 

your

 

gas

 

heater

 

BC

 ‐ 

4200.

 

You’ve

 

definitely

 

made

 

a

 

good

 

choice!

 

Before

 

using

 

the

 

heater

 

please

 

read

 

through

 

the

 

instructions

 

carefully.

 

 

Please

 

note!

 

A

 

gas

 

pressure

 

regulator

 

is

 

absolutely

 

necessary

 

to

 

be

 

used

 

in

 

conjunction

 

with

 

this

 

appliance.

 

 

The

 

gas

 

pressure

 

regulator

 

(which

 

is

 

connected

 

to

 

the

 

gas

 

cylinder)

 

must

 

comply

 

to

 

the

 

applicable

 

standards

 

and

 

be

 

permanently

 

set

 

to

 

a

 

gas

 

pressure

 

of

 

50

 

mbar.

 

If

 

necessary,

 

this

 

can

 

only

 

be

 

exchanged

 

for

 

a

 

similar

 

product

 

with

 

the

 

same

 

properties.

 

Using

 

a

 

regulator

 

with

 

settings

 

other

 

than

 

those

 

specified

 

can

 

lead

 

to

 

serious

 

damage

 

of

 

the

 

heater.

 

 

According

 

to

 

the

 

application

 

we

 

recommend

 

the

 

following

 

gas

 

pressure

 

regulators:

 

 

Dual

 

stage

 

regulator

 

t

‐ 

1.5kg/h;

 

50

 

mbar;

 

small

 

cylinder

 

connection

 

x

 

¼"

 

left

hand

 

thread

 

For

 

the

 

home

 

(all

 

indoor

 

facilities)

 

In

 

accordance

 

with

 

TRF

 

1996

5.2.7.2

 

(amendment

 

as

 

of

 

01.07.2000)

 

and

 

for

 

all

 

commercial

 

liquid

 

gas

 

installations

 

(indoor

 

and

 

outdoor)

 

In

 

accordance

 

with

 

UVV

 

BGV

 

D34

 

paragraphs

 

3

 

and

 

4

 

 

or:

 

 

Regulator

 

1.5kg/h

 

50mbar

 

with

 

 

small

 

cylinder

 

connection

 

x

 

¼"

 

left

hand

 

thread

 

For

 

recreational

 

use,

 

such

 

as

 

on

 

the

 

terrace,

 

outdoors,

 

awnings,

 

party

 

tents

 

etc.

 

with

 

sufficient

 

ventilation

 

 

 

The

 

gas

 

cylinder

 

Only

 

gas

 

cylinders

 

with

 

a

 

maximum

 

capacity

 

of

 

5

 

kg

 

LPG

 

or,

 

if

 

butane

 

gas,

 

up

 

to

 

11

 

kg

 

may

 

be

 

used

 

for

 

this

 

appliance.

 

When

 

using

 

the

 

gas

 

cylinders

 

the

 

following

 

instructions

 

are

 

to

 

be

 

observed:

 

a)

 

the

 

gas

 

cylinder

 

must

 

not

 

be

 

exposed

 

to

 

temperatures

 

higher

 

than

 

50°C.

 

b) 

Gas

 

cylinders

 

that

 

are

 

not

 

connected

 

(either

 

full

 

or

 

empty)

 

must

 

not

 

be

 

stored

 

(over

 

long

 

periods).

 

c)

 

Gas

 

cylinders

 

must

 

not

 

be

 

stored

 

in

 

rooms

 

below

 

the

 

ground

 

floor,

 

nor

 

in

 

cellar

 

vaults,

 

store

 

rooms

 

or

 

stairwells.

 

d) 

Decanting

 

of

 

the

 

gas

 

cylinders

 

is

 

strictly

 

prohibited.

 

 
 

Connecting

 

the

 

gas

 

heater

 

to

 

the

 

gas

 

cylinder

 

In

 

order

 

to

 

connect

 

the

 

appliance

 

the

 

following

 

parts

 

are

 

required:

 

 

Commercial

 

5

 

kg

 

or

 

11

 

kg

 

propane

 

gas

 

cylinder

 

 

Fixed,

 

DVGW

approved

 

pressure

 

regulator,

 

max

 

1.5

 

kg/h.

 

Operating

 

pressure

 

50

 

mbar,

 

suitable

 

for

 

the

 

gas

 

cylinder

 

used

 

 

DVGW

approved

 

hose

 

pipe

 

of

 

sufficient

 

length

 

for

 

installation

 

without

 

kinks

 

(included

 

in

 

delivery)

 

Unscrew

 

the

 

rear

 

panel

 

of

 

the

 

unit

 

and

 

remove.

 

Connect

 

the

 

liquid

 

gas

 

cylinder

 

outside

 

of

 

the

 

appliance

 

as

 

follows:

 

Connect

 

the

 

nut

 

(1)

 

of

 

the

 

pressure

 

regulator

 

(2)

 

by

 

turning

 

firmly

 

to

 

the

 

left

 

with

 

the

 

thread

 

of

 

the

 

cylinder

 

valve

 

(3).

 

Do

 

not

 

use

 

any

 

tools,

 

since

 

tools

 

can

 

damage

 

the

 

seal

 

of

 

the

 

gas

 

cylinder,

 

which

 

can

 

lead

 

to

 

a

 

gas

 

leak.

 

Summary of Contents for 923654

Page 1: ...rarot Gasofen BC 4200 Maximale Leistung 4200 W Verbrauch 305 g h LPG Vor Inbetriebnahme des Ger tes bitte unbedingt die Bedienungsanleitung vollst ndig und aufmerksam durchlesen Bedienungsanleitung zu...

Page 2: ...dieses Ger t d rfen nur Gasflaschen mit einem Fassungsverm gen von 5 maximal 11 kg LPG oder Butangas verwendet werden Beim Gebrauch der Gasflaschen sind die folgenden Hinweise zu beachten a die Gasfl...

Page 3: ...Gasflasche Stellen Sie sicher dass das Flaschenventil der Gasflasche fest geschlossen ist und dass sich in der n heren Umgebung kein offenes Feuer befindet Die Gasflasche aus ihrem Stauraum herausnehm...

Page 4: ...nt zur Vorbeugung vor Brandgefahr und Unf llen die durch hohe Temperatur entstehen k nnen w hrend des Betriebs darf sie daher auf keinen Fall entfernt werden Es ist darauf zu achten dass die Frontpart...

Page 5: ...den Drehknopf noch f r ca 30 Sekunden gedr ckt halten bis sich das Thermoelement einschaltet 5 Den Drehknopf auf eine der drei m glichen Positionen stellen Maximum 3 Mittel 2 Minimum 1 6 Zum Ausschalt...

Page 6: ...ation and use Infrared gas heater BC 4200 Maximum power 4200 W Consumption 305 g h LPG Before using the appliance please read the instructions fully and carefully Keep the instructions in a safe place...

Page 7: ...rrace outdoors awnings party tents etc with sufficient ventilation The gas cylinder Only gas cylinders with a maximum capacity of 5 kg LPG or if butane gas up to 11 kg may be used for this appliance W...

Page 8: ...er out from its storage space making sure that the hose is not stretched or kinked Unscrew the pressure regulator in a clockwise direction Exchange the empty gas cylinder for a full one and place the...

Page 9: ...t not be removed during operation Make sure that the front part of the gas stove is not directed towards curtains armchairs or other flammable materials Therefore the front panel must be directed into...

Page 10: ...the thermocouple switches on 5 Set the rotary knob to one of the three selectable positions Maximum 3 medium 2 minimum 1 6 To turn off the heater close the cylinder valve 1 Minimum 2 Medium 3 Maximum...

Page 11: ...nwijzing Infraroodgaskachel BC 4200 Maximumvermogen 4200 W Verbruik 305 g u LPG Lees voor de ingebruikname absoluut de bedieningshandleiding volledig en aandachtig door Bewaar de bedieningshandleiding...

Page 12: ...en lucht voortent partytent enz met voldoende verluchting en ontluchting De gasfles Voor dit apparaat mogen alleen gasflessen met een volume van 5 tot maximum 11 kg LPG of butaangas gebruikt worden Bi...

Page 13: ...rdt Vervangen van de gasfles Verzeker u ervan dat het gasventiel van de gasfles goed gesloten is en dat er in de onmiddellijke omgeving geen open vuur is Neem de gasfles uit de opbergruimte en let er...

Page 14: ...kingen De voorste afdekking van deze gaskachel dient om brandgevaar en ongevallen te voorkomen die door hoge temperaturen kunnen ontstaan Tijdens de werking mag deze dus in geen geval verwijderd worde...

Page 15: ...akvlam brandt de draaikop nog gedurende ongeveer 30 seconden ingedrukt tot het thermo element ingeschakeld wordt 5 Zet de draaiknop op een van de drie mogelijke standen maximum 3 medium 2 minimum 1 6...

Page 16: ...Puissance maximale 4200 W Consommation 305 g h LPG Avant de mettre l appareil en service veuillez lire soigneusement la notice d utilisation dans sa totalit Conservez la notice d utilisation dans un...

Page 17: ...le de 11 kg de LPG ou de butane Lors de l utilisation de bouteilles de gaz prendre garde aux points suivants a La bouteille de gaz ne doit pas tre soumise une temp rature sup rieure 50 C b Les bouteil...

Page 18: ...ni plier le tuyau D vissez le d tendeur en tournant dans le sens des aiguilles d une montre Remplacez la bouteille de gaz vide par une pleine et placez la bouteille vide dans un lieu s r Replacez le...

Page 19: ...Il ne doit en aucun cas tre t pendant le fonctionnement Il est important de s assurer que l avant du po le ne soit pas face des rideaux des fauteuils ou d autres mat riaux inflammables Dirigez toujour...

Page 20: ...le thermocouple s allume 5 Tournez le bouton sur l une des trois positions possibles Maximum 3 Moyen 2 Minimum 1 6 Pour arr ter le po le fermez le robinet de la bouteille de gaz 1 Minimum 2 Moyen 3 M...

Page 21: ...nfrarossi BC 4200 Potenza massima 4200 W Consumo 305 g h LPG Prima di utilizzare l apparecchio necessario leggere le istruzioni per l uso con attenzione e per intero Conservare in un luogo sicuro le i...

Page 22: ...d aria in entrata e in uscita La bombola del gas Su questo apparecchio possibile utilizzare esclusivamente bombole di gas liquido GPL o butano dalla capacit massima tra 5 e 11 kg Osservare le seguent...

Page 23: ...tenzione a non piegare o a non creare spire nel tubo flessibile Svitare in senso orario il regolatore di pressione Sostituire la bombola vuota con una nuova bombola e riporre quella vuota in un luogo...

Page 24: ...ante l uso della stufa Fare attenzione che la parte anteriore della stufa non sia posta in direzione di tende poltrone o altri oggetti facilmente infiammabili dirigere sempre la parte anteriore verso...

Page 25: ...enere premuta la manopola per circa trenta secondi fino a quando non si attiva l elemento riscaldante 5 Impostare la manopola su una delle tre regolazioni a disposizione Massimo 3 Medio 2 Minimo 1 6 P...