22
Set-Up and Operation
If the
- symbol (battery symbol) appears in the display, replace the
battery.
If the unit is not used for more than 7 minutes, it automatically turns off
to save battery power.
Sensors on the Unit
On the front of the Unit are the following
Sensors:
1
Æ
Infrared Sender
2
Æ
Ultrasound Receiver
3
Æ
Ultrasound Sender
Calibration of the Unit
The unit is suitable for use indoors and outdoors, it is equipped with an
automatic temperature compensation for the temperature range between 0 -
38 °C.
The unit has been calibrated for 760 mmHg pressure (1 Bar) and 50 %
humidity. If you want to use the unit under different conditions, measuring
errors may occur. To avoid such errors, calibrate the unit.
Do as follows:
Set the Unit to the position (1).
Set a distance of exactly 3m to a straight wall with a rule or measuring tape.
Press and hold the buttons
and
at the same time and
additionally press
. The unit
turns on and executes the
measurement. If the unit has
calibrated correctly, 3.00 m
appears in the display.