Programming
20
Programming both Gate Openers
1.
As soon as the control box is connected to power mains, the display starts
flashing and shows “
– –
“. Now the unit is in Standby.
2.
Hold the button
FUNC
pressed for more than 4 seconds.
The display shows
P1
. The unit is in setting mode for operating 1 resp. 2
gate openers.
3.
Press the buttons
INC
(for Increase) or
DEC
(for Decrease) in order to start
settings.
Setting
11
indicates operating mode for both gate openers (factory setting).
4.
Press the button
FUNC
in order to store the data. The display shows
P2
.
P2 Setting Master/Slave Gate
The display shows
P2
. The uni
t is now in setting mode for “Master/Slave
gate
“.
Master gate means, the selected gate will open first and close last and
Slave gate means, the second gate will open with time delay and close first.
1.
Press the buttons
INC
or
DEC
.
01
indicates the gate opener 1 will open and close as Master gate.
10
indicates that gate opener 2 will open and close as Master gate.
2.
Press the button
FUNC
to store the settings.
The display shows
P3
.
The unit is now in the mode “Master/Slave Open
Interval”.
P3 Setting the Master/Slave Open Interval
1.
Press the button
INC
or
DEC
in order to adjust the open interval.
Setting
0
indicates that Master gate and Slave gate open simultaneously.
Setting 1 indicates that the Master gate will open 1 second before the Slave
gate.
Setting
2
indicates that the Master gate will open 2 seconds before the Slave
gate.
Settings from 0
– 9 are possible. Each time you press the button
INC
, the
value will increase and when pressing the button
DEC
, the value will de-
crease. Factory setting is 3 seconds.
2.
Press the button
FUNC
in order to store the settings.
The display shows
P4
. The unit is now in the mode
“Master/Slave Close
Interval”.