Use the following charging current for the listed lead-acid battery ratings.
Use 1 ampere for batteries from 3 to 12 Ah.
Use 4 amperes for batteries from 13 to 32 Ah.
Use 7 amperes for batteries from 33 to 50 Ah.
Use 10 amperes for batteries from 51 Ah up.
SPECIFICATIONS
Maximum Voltage:
18 Volts DC
Maximum Current:
40 Amperes
Circuit:
Diode OR-Gate
Diodes:
Two Schottky 80 Ampere, 20 Volt
Voltage Drop:
0.25 VDC Quiescent
0.37 VDC at 40 Amperes
Charging Circuit:
Charging regulator IC
Field Effect Pass Transistor
Schottky Diode
Fuse switched for 1, 4, 7, or 10 Amperes ( +2,-8%) maximum
Peak voltage limit: 13.8 (Gelled Cells),
14.2 (AGM), (+,-2%)
Peak voltage terminate point: 1/10 maximum current
Float Voltage: 13.5 volts (+,-2%)
Reference voltages are temperature compensated
Connectors:
Anderson Powerpole®, 40A
Size:
5.25 x 3.90 x 1.65 in, 13.4 x 9.9 x 4.2 cm
Weight:
0.9 lbs, 0.4 kg
Mounting Holes:
Two, 0.175 d, at 4.875 in. distance, for #8 hardware