35
Color Sensor
8. Interfaces
8.1. RS-232
The RS-232 port makes use of the software handshake procedure. All settings can be configured and queried
via a computer. RS-232 port terminals RxD (5) and TxD (4) are linked to minus (pin 3), and can be connected
to the corresponding terminals at the communication partner.
Technical Data, RS-232 Port
Adjustable baud rate, 8 data bits, no parity, 1 stop bit
Connect the sensor to the PC or the controller as follows using wenglor’s S232W3 interface cable:
• Insert the S232W3 interface cable into plug no. 2 directly at the sensor.
• Plug the ZAS89xxx 8-conductor connection cable into the interface cable.
• Connect the 9-pin D-sub pug connector on the S232W3 cable to the serial port, or to the PC or controller
via the AB-USB01 USB adapter.
Stromversorgung einschalten
8.2. IO-Link
Process and parameters data can be found at www.wenglor.com in the product’s separate download area:
www.wenglor.com
→
Product World
→
Search (Enter the product number)
→
Download
9. Maintenance Instructions
NOTE!
• This wenglor Sensor is maintenance-free.
• It is advisable to clean the lens and the display, and to check the plug connections at regular inter-
vals.
• Do not clean with solvents or cleansers which could damage the device.
• The product must be protected against contamination during initial start-up