5. Installation and Electrical Connection
5.1. Installation
• Protect the product against contamination during installation
(see section „2.5. General Safety Precautions“ on page 7)
• Observe all applicable electrical and mechanical regulations, standards, and safety rules.
• Protect the product against mechanical influences.
• Make sure that the sensor is mounted in a mechanically secure fashion.
• The use of corresponding end brackets is recommended for mounting to DIN rails.
• In order to avoid damaging the LED lens, always connect a fiber-optic cable or attach the rubber protector.
Attaching Glass Fiber-Optic Cables
• Remove the protective cap from the sensor before attaching fiber-optic cables.
• Protect fiber-optic cables from mechanical influences!
1 Color Sensor
3 adapter No. 1
2 wenglor® Fiber Optic
4 Sleeve Nut
ATTENTION!
Risk of property damage in case of improper installation!
The product may be damaged.
– Comply with installation instructions.
5.2. Electrical Connection
• Connect the sensor to 10 ... 30 V DC at plug no. 1 and/or 2 and/or 3, depending on which outputs are
required (see „3.2. Connection Diagram“ on page 10)