21
Fiber Optic Cable Sensor
7. IO-Link
Parameter data can be found in the interface protocol under:
www.wenglor.com
è
Product World
è
Search (Enter the product number)
è
Download
è
Interface protocol
8. Add-on Modules
8.1. Connect the Add-on Modules
Up to 12 Add-on Modules (ODX402P0099) can be connected to the Sensor. At each Add-on Module another
Plastic Fiber Optic Cable can be connected, The Add-on Modules are configured like the Sensors of the Basic
Module via the menu. The Add-on Module can be connected to the Basic Module before operation or during
operation through the plug connection. We suggest to use end brackets for the DIN-Rail.
The Basic Module signalizes in the display that an Add-on Module has been connected. In order to configure
this Module a Sensor number between 4 and 15 has to be attributed. Select the number with key
5
and
6
and confirm with the enter key.
The Sensor confirms the distribution of the Sensor number in its dis-
play.
The Add-on Module is generally attributed to the closest output that is
still free. In the menu “Outputs” this attribution can be changed.
In the menu Sensors the Add-on Module can be configured. Therefor the Sensor has to be selected with the
keys
5
and
6
and has to be confirmed with the enter key (view chapter “Sensors” on page 11).
8.2. Disconnect the Add-on Modules
There are two possibilities to disconnect one or several Add-on Modules:
1. without previous reset
2. with previous reset
In case of disconnection without previous reset the Add-on Module is disconnected during operation or in OFF
status from the Basic Module.
Here the configurations of the Module and the Sensor number are kept.
If this Add-on Module is connected with another system afterwards, where the Sensor number is already taken,
a double attribution and thus an error will occur.
Thus we suggest to reset the Sensor before disconnecting it from the Basic Module.
In case of disconnection with previous reset the Sensor is reseted (like in chapter “Reset” on page 19) and
then disconnected from the Basic Module. If this Add-on Module is connected with another system afterwards,
a new Sensor number has to be attributed first.