11
Fiber Optic Cable Sensor
6. Settings
6.1. Run
The Sensor is switched to the display mode when the enter key is pressed.
Received Signal Strength
(numeric value 0 – 999)
Bar chart of received
Signal Strength
Switching Status:
Dark dot = Sensor connected
Blinking = Contamination
6.2. Sensors
In the menu Sensors the connected Sensors are configured. Therefor select one of the connected Sensors,
or all Sensors (Global) with the navigation keys and the enter key. The Sensor(s) then can be configured.
6.2.1 Teach-In
Function
Description
T Normal
Normal Teach-In
The object is taught in by pressing the T key:
• Align the spot to the object.
• Briefly press the T key.
è
The switching distance
to the object is set.
• If necessary, readjust the
switching distance with the help
of the “Potentiometer” menu item.
T Minimal
Minimal Teach-In/Glass recognition
The object is taught in by pressing the T key:
• Align the spot to the object.
• Briefly press the T key.
è
The switching distance to the
object is set.
• If necessary, readjust the
switching distance with the help
of the “Potentiometer” menu item.
Object
Object-
distance (OA)
Calculated
switching
distance is
approximately
50% > OA
Object
Object-
distance (OA)
Calculated
switching
distance is
approximately
17% > OA
Summary of Contents for ODX402P0088