7.9. Display
Display
Setting the Display
Rotate
Intensity
Mode
Back
Run
Rotate:
Rotate the display 180°.
The display is rotated 180° by pressing the
key. The display can
be returned to its original position by pressing the same key once
again.
Intensity:
Adjust display intensity.
Mode:
Select display mode.
7.9.1. Display – Mode
Mode
Selecting a Display Mode
|
E/A
|
Match code
|
Text
|
Reading performance
Back
Run
E/A:
The statuses of the individual inputs and outputs, as well as the last
code to be read in, are displayed.
Match code:
The taught in master code and the currently scanned code appear
at the display. If the two codes match up with each other, the master
code is displayed inversely.
Text:
A freely selectable text can be written to the display by means of an
interface command. The last code to be read in is displayed as well.
Reading performance:
Reading performance is displayed in scans per second, and as a
percentage. Calculation of reading performance is deactivated as a
default setting. It can be activated via the web-based configuration or
by means of an interface command.
7.9.2. Display – Intensity
Intensity
Setting Display intensity
|
Min
|
Normal
|
Max
|
Power save
|
Screensaver
Back
Run
Min:
Minimum intensity.
The display’s intensity is set to a minimal value.
Normal:
Normal intensity.
The display’s intensity is set to a medium value.
Max:
Maximum intensity.
The display’s intensity is set to the maximum value.
Power save:
Energy saving mode.
If no keys are pressed for a period of one minute, the display is
switched off and is automatically switched back on as soon as a key
is activated.
Screensaver:
The display is inverted once a minute.