14
EN
For Trigger Input
When a pin is configured as a trigger input, the following functions can be set up:
E1 Trigger/
E2 Trigger/
E3 Trigger/
E4 Trigger
Basic Scanner settings for the individual inputs are entered to the
E1/E2/E3/E4
Trigger menu.
|
At Ub
|
At 0 V
Back
Run
At Ub:
The input is activated when supply power (Ub) is on.
At 0 V:
The input is activated when supply power is off.
For New Master
When a pin is configured as a New Master input, the following functions can be set up:
E1 New Master/
E2 New Master/
E3 New Master/
E4 New Master
Basic Scanner settings for the individual inputs are entered to the
E1/E2/E3/E4 New
Master menu.
|
At Ub
|
At 0 V
Back
Run
At Ub:
The input is activated when supply power (Ub) is on.
At 0 V:
The input is activated when supply power is off.
7.3.1. Output – NPN/PNP
NPN/PNP
Configuring the outputs
PNP
NPN
Pushpull
Back
Run
PNP:
A load or an analysis module is connected between the minus pole
(reference) and the output. When switched, the output is connected
to the plus pole via an electronic switch.
NPN:
A load or an analysis module is connected between the plus pole
(reference) and the output. When the scanner is switched, the output
is connected to the minus pole via an electronic switch.
Pushpull:
Push-pull output.
Works like an electronic switch, which switches the output alternately
to the plus pole or the minus pole.
7.3.2. Output – NO/NC
NO/NC
Configuring the outputs
NO
NC
Back
Run
NO:
Normally open contact, light switching.
The output is deactivated as soon as the set event (Good Read,
Match, Mismatch or No Read) occurs.
NC:
Normally closed contact, dark switching.
The output is activated as soon as the set event (Good Read, Match,
Mismatch or No Read) occurs.