16
EN
7.3.5. Output – Pulse Length
Pulse Length defines the duration of the switching status. This function can be combined with ON Delay.
Code
Impulse
Pulse combined
with ON Delay
Pulse Length
ON Delay
Pulse Length
Impulse
Adjusting Pulse Length
Pulse Length in ms
Pulse duration can be adjusted within a range of 0 to 1000 ms by pressing the “+”
or “–” key. Quicker scrolling through numbers is made possible by pressing and
holding the respective key.
7.4. E/A Test
This function changes the outputs manually, regardless of the Scanner’s momentary reading results. This
makes it possible to determine whether or not outputs are correctly connected, for example to a controller. It’s
also possible to test whether or not voltage is applied to an input pin.
After selecting the pin function, one of the following menus appears.
Each of the menus includes the following items:
E/A Test
E/A: Testing of Inputs and Outputs
Test A1
Test A2
Test A3
Test A4
Back
Run
Test A1:
Test output 1
Test A2:
Test output 2
Test A3:
Test output 3
Test A4:
Test output 4
7.4.1. E/A Test – Testing A1 through A4
Test A1/Test A2/
Test A3/Test A4
Activating or Deactivating Outputs
|
ON
|
OFF
Back
Run
ON:
Activate output
OFF:
Deactivate output