Figure 10- Fuel Valve in the “on” position
Figure 12- Pulling the start cord
Figure 11- Pull choke out for closed position.
Push in for open position.
SUBSEQUENT STARTING OF THE GENERATOR
If this is not the first time using the generator, user should take the following steps to prepare it for
operation.
IMPORTANT:
At this point the user should be familiar with the procedures described in the
section titled “Using the Generator for the First Time.” If the user has not yet read this
section, go back and read it now.
Step 1- Check the Oil
Oil consumption is normal during generator usage. The generator is equipped with a low-oil
shutoff to protect it from damage. The oil level in the engine should be checked before each use to
ensure that the engine crankcase contains sufficient lubricant.
To check or add oil, follow these steps:
1.
Make sure the generator is on a level surface. Clean around oil fill.
2.
Remove the oil filler/dipstick cap and check oil level.
3.
If oil level is below the second thread from the lip of the oil fill opening, slowly add oil
until the engine crankcase is filled.
4.
Reinstall and tighten oil filler cap before starting the engine. .
Step 2 – Check the Gas Level
Before starting the generator, check to see that there is sufficient gasoline in the fuel tank. The fuel
gauge on top of the generator will indicate the fuel level in the tank. Add gasoline if necessary but
leave sufficient room in tank for expansion.
17
Summary of Contents for 56877
Page 34: ...ENGINE EXPLODED VIEW AND PARTS LIST 31...
Page 36: ...GENERATOR EXPLODED VIEW AND PARTS LIST 33...
Page 38: ...WIRING DIAGRAM 35...
Page 40: ...NOTES 37...