89
LOW SODIUM
BROMIDE ERROR
Low Sodium Bromide Error
(Err) occurs when the sodium
bromide level is too low. The lo
LED indicator will blink when
the error is present. The in.clear
system will not generate
bromine until the Low Sodium
Bromide Error (Err) is cleared.
To clear the Low Sodium
Bromide error (Err), add sodium
bromide to the hot tub water.
Let water circulate for 5 min-
utes. Activate diagnostic mode
and add more sodium bromide
until gauge is back in the green
zone. Exit diagnostic mode.
LOW SODIUM BRO-
MIDE WARNING
Low Sodium Bromide
Warning (Lo) indicates the need
to add sodium bromide to the
hot tub water.
In diagnostic mode, add
sodium bromide to the water
until the gauge reaches the
green zone to clear a Low Sodi-
um Bromide Warning (Lo).
If after adding sodium
bromide the Low Sodi-
um Bromide Warning
(Lo) or Low Sodium
Bromide Error (Err) still
occurs it could be the
result of:
• calcification of the
electrolytic plates;
• airlocks trapped in
the in.clear unit or
insufficient flow;
• internal pressure
switch problem.
BLINKING “AC”
A blinking “AC” message dis-
played on the keypad indicates
that there is a problem with the
power input. The most common
reason is that the in.clear unit
is supplied with 120 V instead
of 240 V.
Please make sure power cord
is connected properly to a 240
V source.
STANDALONE
VERSION ONLY:
BROMINE GENER-
ATION INDICATOR
BLINKING
A blinking Bromine Generation
LED means that the system is
unable to generate bromine
because no water flow is
detected by the in.clear system.
This situation is normal if
the pump is not running and
no water is flowing through
the in.clear. However, if
water is circulating through the
in.clear unit, and the Bromine
Generation LED is still blinking,
make sure that the in.clear is
installed on the pressure side
of the pump and that water is
properly flowing through the
in.clear unit.
BROMINE GENER-
ATION INDICATOR
IS OFF
The Bromine Generation LED in-
dicator is OFF when there is no
need for bromine generation.
This situation is normal, espe-
cially with low maintenance
level of bromine generation set
on the keypad.
TROUBLESHOOTING
OPTIONAL ACCESSORIES - IN.CLEAR
Summary of Contents for Amazon W-Flow
Page 1: ...USER MANUAL FOR HOT TUB CONTROL SYSTEMS KEYPADS ACCESSORIES ...
Page 19: ...MAJOR COMPONENTS OF THE PRODUCT 19 OLYMPUS ...
Page 20: ...MAJOR COMPONENTS OF THE PRODUCT 20 MONT BLANC ELBRUS 230 ...
Page 21: ...MAJOR COMPONENTS OF THE PRODUCT 21 MONTE BIANCO DISCOVERY ...
Page 22: ...MAJOR COMPONENTS OF THE PRODUCT 22 MONTE ROSA KILIMANJARO ...
Page 23: ...MAJOR COMPONENTS OF THE PRODUCT 23 PARIS ELBRUS 2018 ...
Page 24: ...MAJOR COMPONENTS OF THE PRODUCT 24 LONDON MALAGA 2018 ...
Page 25: ...MAJOR COMPONENTS OF THE PRODUCT 25 MILAN PALERMO 2018 ...
Page 26: ...MAJOR COMPONENTS OF THE PRODUCT 26 BERLIN MARBELLA 2018 ...
Page 27: ...MAJOR COMPONENTS OF THE PRODUCT 27 TAURUS KILIMANJARO ...
Page 28: ...MAJOR COMPONENTS OF THE PRODUCT 28 LIBRA ELBRUS 230 ...
Page 29: ...MAJOR COMPONENTS OF THE PRODUCT 29 HERCULES ...
Page 30: ...MAJOR COMPONENTS OF THE PRODUCT 30 LEO P P ...
Page 31: ...MAJOR COMPONENTS OF THE PRODUCT 31 LEO SCANDI PACK ...
Page 32: ...MAJOR COMPONENTS OF THE PRODUCT 32 ORION P P ...
Page 33: ...MAJOR COMPONENTS OF THE PRODUCT 33 ORION SCANDI PACK ...
Page 34: ...MAJOR COMPONENTS OF THE PRODUCT 34 RIO GRANDE W FLOW ...
Page 35: ...MAJOR COMPONENTS OF THE PRODUCT 35 AMAZON W FLOW ...
Page 36: ...MAJOR COMPONENTS OF THE PRODUCT 36 DANUBE W FLOW ...
Page 133: ...W3000 W5000 WIRING DIAGRAM W3000 W5000 133 ...
Page 136: ...WIRING DIAGRAM W8000 136 ...
Page 143: ......