background image

Page 2 of 14 

Table of contents 

 
 

1. 

Description 

         5 

Technical data 

 

 

 

 

 

 

 

 

 

6

 

 

2. 

Placing 

in 

operation 

        6

 

2.1 

Manual 

operating 

mode 

        

6

 

2.2 

Automatic 

operating 

mode 

       

7

 

2.3 

Setting 

temperature 

profile 

       

9

 

2.4 

Starting 

program 

execution 

       

9

 

2.5 

Control 

of 

the 

vacuum 

function 

       

10

 

2.6  Saving and loading temperature-time profiles   

 

 

 

 

10

 

 

3. 

External 

sensor 

         11 

3.1  External sensor with measuring function (MEASURE MODE)  

 

 

11

 

3.2 

Teach 

in 

Mode 

procedure        

11

 

3.3  External sensor with control function (CONTROL MODE) 

 

 

 

11

 

 
4. 

Lock 

Mode          12 

 
5. 

Switching 

Temperature 

Conversion 

      12 

 
6. 

Interface 

RS232 

         12 

 
7. 

Operating 

guidelines 

        12 

 
8. 

Fault 

messages 

         12 

 
9. 

Accessories 

         13 

 
10. 

Scope 

of 

supply 

         13 

 
11. Hot Air Nozzles   

 

 

 

 

 

 

 

 

14 

 
12. 

Quick 

Reference 

         15 

 

 

 

 

 

 

 

 

Summary of Contents for WHA 3000VS

Page 1: ...Weller Tools GmbH Carl Benz Str 2 74354 Besigheim Germany Tel 49 0 7143 580 0 Fax 49 0 7143 580 108 WHA 3000V Hot Air Station Operating Instructions Version 2 3...

Page 2: ...m function 10 2 6 Saving and loading temperature time profiles 10 3 External sensor 11 3 1 External sensor with measuring function MEASURE MODE 11 3 2 Teach in Mode procedure 11 3 3 External sensor wi...

Page 3: ...ol key time specification auto mode preheating temperature 6 AIR Control key air volume 7 TEMP Control key hot air temperature 8 LED Indicator Vacuum 9 LED Indicator START STOP 10 START STOP Control k...

Page 4: ...erface 15 PC Interface RS232 16 Connection for External Sensor Type K 17 Hand piece Connecting Hose 18 Connection for Compressed air 19 Connection for Nitrogen N2 400 600k Pa 20 Stand Switch Connectio...

Page 5: ...ities for use of this repair station The hot air temperature at the hand piece can be adjusted within the range of 50 C 550 C 122 F 999 F Through an external compressed air supply or nitrogen N2 as an...

Page 6: ...ing pressure is required The nitrogen connection 19 serves to generate hot air The compressed air connection 18 serves to generate vacuum by means of a compressed air converter If a separate nitrogen...

Page 7: ...air flow rate 200 C 392 F 5l min Note Hot air is automatically disabled after 999 sec for safety reasons 2 2 Automatic operating mode The Automatic operating mode has a 3 step temperature time profil...

Page 8: ...ce Nozzle temperature during the first step Depressed Twice Temperature of the bottom heater during the first step only with WHP3000 Repeat for Steps 1 3 Symbol for nozzle or bottom heater indicates w...

Page 9: ...from the Locked center position It must remain in position directly over the Hot Plate to allow for the WHA 3000V to operate 2 5 Control of the vacuum function The nozzle vacuum are activated Directl...

Page 10: ...riefly in the display 1 THERMOCOUPLE or THERMOCOUPLE MEASURE MODE CONTROL MODE Both operating modes only become active once the external sensor 16 has been connected 3 1 External Sensor with measuring...

Page 11: ...y be operated using the START STOP 10 and VAC 11 Control Keys 5 Switching Temperature Conversion By pressing the Control Key Temp 7 when switching on the unit 4 you can toggle between the operating mo...

Page 12: ...C LOCKED WHA locked lock function Unlock WHA TOOL STAND AKT30 Stand or WBH3000 Proximity Sensor Connect to socket 20 not connected 9 Accessories 0053119099 External sensor type K 0 5mm 0058754951 Exte...

Page 13: ...2 sides heated Type ND 005 87 368 39 NQT Hot air nozzle 22 0 x 22 0 mm 005 87 368 41 NQT10 Hot air nozzle 14 8 x 14 8 mm 005 87 368 42 NQT25 Hot air nozzle 18 0 x 18 0 mm 005 87 368 43 NQT Hot air noz...

Page 14: ...etting hot air temperature manual mode Setting hot air temperature and bottom heater for step 1 3 auto mode Setting flow rate manual mode setting flow rate for step 1 3 auto mode Time setting for step...