Page 11 of 14 

temperatures (stage 1-3) have been reached. The times determined in this manner are shown after 
the soldering or desoldering process in the display (1) and can be saved. 
 

3.3 External sensor with control function "CONTROL MODE"

 

The temperature of the external sensor is controlled in this operating mode. The external sensor 
records the actual value (control variable) for the temperature control. The setting for the setpoint 
value at the unit must therefore be adapted to the measured temperature (actual value) of the 
external sensor. The actual value of the external sensor is shown in the display (1).  
 
      External 

sensor 

active 

in 

"CONTROL 

MODE" 

 

 

 

 

 

 

 

 

 
 
 
 
 
A basic prerequisite for faultless application is direct contact of the sensor on the assembly or 
component.

 

 

4. Lock Mode  

The device can be locked by inserting and removing a coded plug in socket (21). The current 
soldering parameters cannot be further changed. The WHA 3000P can only be operated using the 
START/STOP (10) and VAC (11) Control Keys. 
 
 

5. Switching Temperature Conversion 

By pressing the Control Key "

Temp

" (7) when switching on the unit (4), you can toggle between the 

operating modes "

°C

" and "

°F

". The following appears briefly in the display (1): 

 
 
 
 

 

 

 

 

      or   

 

 

 
 
 

6. RS232 interface 

Using additional software, the device can be operated completely via the RS232 interface (21). 
 
 

7. Work instructions 

The hot air nozzle is designed such that the vacuum plate lies flat on the component. The vacuum 
plate is also used for the transfer of heat. When the vacuum is enabled, the component can be lifted 
after the solder has reflowed. Here it is important to pre-heat the vacuum plate to operating 
temperature prior to de-soldering. As an option, it is possible to use a vacuum cup in place of the 
vacuum plate. 
 

Nozzle change 

 

Caution:   Risk of burns! The hot air nozzle remains hot for some time after power off or 

removal. 

 
The hot air nozzles are fastened to the heating element using a clamping screw. To change the 
nozzle, loosen the screw and remove the hot gas nozzle using the Nozzle Change Tool provided. 

 

TEMP AIR 

PREHEAT

 

 

 

 

 

250 °C 

25 l 

OFF 

 

 

 

 

°F 

°C 

Summary of Contents for WHA 3000VS

Page 1: ...Weller Tools GmbH Carl Benz Str 2 74354 Besigheim Germany Tel 49 0 7143 580 0 Fax 49 0 7143 580 108 WHA 3000V Hot Air Station Operating Instructions Version 2 3...

Page 2: ...m function 10 2 6 Saving and loading temperature time profiles 10 3 External sensor 11 3 1 External sensor with measuring function MEASURE MODE 11 3 2 Teach in Mode procedure 11 3 3 External sensor wi...

Page 3: ...ol key time specification auto mode preheating temperature 6 AIR Control key air volume 7 TEMP Control key hot air temperature 8 LED Indicator Vacuum 9 LED Indicator START STOP 10 START STOP Control k...

Page 4: ...erface 15 PC Interface RS232 16 Connection for External Sensor Type K 17 Hand piece Connecting Hose 18 Connection for Compressed air 19 Connection for Nitrogen N2 400 600k Pa 20 Stand Switch Connectio...

Page 5: ...ities for use of this repair station The hot air temperature at the hand piece can be adjusted within the range of 50 C 550 C 122 F 999 F Through an external compressed air supply or nitrogen N2 as an...

Page 6: ...ing pressure is required The nitrogen connection 19 serves to generate hot air The compressed air connection 18 serves to generate vacuum by means of a compressed air converter If a separate nitrogen...

Page 7: ...air flow rate 200 C 392 F 5l min Note Hot air is automatically disabled after 999 sec for safety reasons 2 2 Automatic operating mode The Automatic operating mode has a 3 step temperature time profil...

Page 8: ...ce Nozzle temperature during the first step Depressed Twice Temperature of the bottom heater during the first step only with WHP3000 Repeat for Steps 1 3 Symbol for nozzle or bottom heater indicates w...

Page 9: ...from the Locked center position It must remain in position directly over the Hot Plate to allow for the WHA 3000V to operate 2 5 Control of the vacuum function The nozzle vacuum are activated Directl...

Page 10: ...riefly in the display 1 THERMOCOUPLE or THERMOCOUPLE MEASURE MODE CONTROL MODE Both operating modes only become active once the external sensor 16 has been connected 3 1 External Sensor with measuring...

Page 11: ...y be operated using the START STOP 10 and VAC 11 Control Keys 5 Switching Temperature Conversion By pressing the Control Key Temp 7 when switching on the unit 4 you can toggle between the operating mo...

Page 12: ...C LOCKED WHA locked lock function Unlock WHA TOOL STAND AKT30 Stand or WBH3000 Proximity Sensor Connect to socket 20 not connected 9 Accessories 0053119099 External sensor type K 0 5mm 0058754951 Exte...

Page 13: ...2 sides heated Type ND 005 87 368 39 NQT Hot air nozzle 22 0 x 22 0 mm 005 87 368 41 NQT10 Hot air nozzle 14 8 x 14 8 mm 005 87 368 42 NQT25 Hot air nozzle 18 0 x 18 0 mm 005 87 368 43 NQT Hot air noz...

Page 14: ...etting hot air temperature manual mode Setting hot air temperature and bottom heater for step 1 3 auto mode Setting flow rate manual mode setting flow rate for step 1 3 auto mode Time setting for step...

Reviews: