2.4 Starting program 

The soldering process and thus the 3-step temperature-time profile is started: 
 
Directly on the Control Panel:  

 

START/STOP 

(10) Control Key, LED (9) illuminates. 

 
2-Position Foot Switch (21): 

START/STOP

 corresponds to setting 1 of the foot switch 

(hot air and vacuum are only active when pressed) 

 

Foot Switch Position 1-Air, Position 2-Vacuum 

 
Manual Control Console (21):  

 

START/STOP

 using the 

AIR

 Control Key 

(Optional) 
  
The nozzle temperature, air flow rate and the time remaining are indicated on the display (1). The 
active program step is marked on the display. 
 
When the hand-piece is placed in the safety stand, the program is interrupted and the hot air 
switched off by an integrated contact. When the nozzle pre-heating is active (PREHEAT ON), the 
device switches to the standby mode with reduced temperature and air flow rate. 
 

Note: When using the WBH 3000S Circuit Board Holder (20), the WHA 3000V will 
automatically turn “off” if the position of the Z-axis Head is moved from the “Locked” center 
position. It must remain in position directly over the Hot Plate to allow for the WHA 3000V to 
operate. 

 
 

2.5 Control of the vacuum function 

 
The nozzle vacuum are activated: 
 
Directly on the Control Panel:  

VAC 

(11) Control Key, LED (8) illuminates. 

 
2-Position Foot Switch (21):   

vacuum corresponds to Position 2 of the foot switch 

 
Manual Control Console (21): 

using the VAC Control Key 

(Optional) 
 

If the 

VAC

 Control Key (11) is pressed prior to the start of a de-soldering process, the 

vacuum integrated into the nozzle is activated automatically at the end of the process. The 
vacuum function can also be enabled and disabled manually at any time during the 
soldering process. If the vacuum is enabled during a soldering process, there is no 
automatic activation at the end of the process. 

 

 

Note: If the nozzle temperature is above 250°C/482°F the vacuum is automatically disabled 
after 90 sec for safety reasons. 
 
 
2.6 Saving and loading temperature-time profiles 

A total of 10 temperature-time profiles can be saved. A default profile is saved in the 10 program 
memories in the factory. 
 
Press 

UP/DOWN 

Control Keys (2)/(3) simultaneously until the following menu appears on the 

display (1)  

 

 
 
 

Summary of Contents for WHA 3000VS

Page 1: ...Weller Tools GmbH Carl Benz Str 2 74354 Besigheim Germany Tel 49 0 7143 580 0 Fax 49 0 7143 580 108 WHA 3000V Hot Air Station Operating Instructions Version 2 3...

Page 2: ...m function 10 2 6 Saving and loading temperature time profiles 10 3 External sensor 11 3 1 External sensor with measuring function MEASURE MODE 11 3 2 Teach in Mode procedure 11 3 3 External sensor wi...

Page 3: ...ol key time specification auto mode preheating temperature 6 AIR Control key air volume 7 TEMP Control key hot air temperature 8 LED Indicator Vacuum 9 LED Indicator START STOP 10 START STOP Control k...

Page 4: ...erface 15 PC Interface RS232 16 Connection for External Sensor Type K 17 Hand piece Connecting Hose 18 Connection for Compressed air 19 Connection for Nitrogen N2 400 600k Pa 20 Stand Switch Connectio...

Page 5: ...ities for use of this repair station The hot air temperature at the hand piece can be adjusted within the range of 50 C 550 C 122 F 999 F Through an external compressed air supply or nitrogen N2 as an...

Page 6: ...ing pressure is required The nitrogen connection 19 serves to generate hot air The compressed air connection 18 serves to generate vacuum by means of a compressed air converter If a separate nitrogen...

Page 7: ...air flow rate 200 C 392 F 5l min Note Hot air is automatically disabled after 999 sec for safety reasons 2 2 Automatic operating mode The Automatic operating mode has a 3 step temperature time profil...

Page 8: ...ce Nozzle temperature during the first step Depressed Twice Temperature of the bottom heater during the first step only with WHP3000 Repeat for Steps 1 3 Symbol for nozzle or bottom heater indicates w...

Page 9: ...from the Locked center position It must remain in position directly over the Hot Plate to allow for the WHA 3000V to operate 2 5 Control of the vacuum function The nozzle vacuum are activated Directl...

Page 10: ...riefly in the display 1 THERMOCOUPLE or THERMOCOUPLE MEASURE MODE CONTROL MODE Both operating modes only become active once the external sensor 16 has been connected 3 1 External Sensor with measuring...

Page 11: ...y be operated using the START STOP 10 and VAC 11 Control Keys 5 Switching Temperature Conversion By pressing the Control Key Temp 7 when switching on the unit 4 you can toggle between the operating mo...

Page 12: ...C LOCKED WHA locked lock function Unlock WHA TOOL STAND AKT30 Stand or WBH3000 Proximity Sensor Connect to socket 20 not connected 9 Accessories 0053119099 External sensor type K 0 5mm 0058754951 Exte...

Page 13: ...2 sides heated Type ND 005 87 368 39 NQT Hot air nozzle 22 0 x 22 0 mm 005 87 368 41 NQT10 Hot air nozzle 14 8 x 14 8 mm 005 87 368 42 NQT25 Hot air nozzle 18 0 x 18 0 mm 005 87 368 43 NQT Hot air noz...

Page 14: ...etting hot air temperature manual mode Setting hot air temperature and bottom heater for step 1 3 auto mode Setting flow rate manual mode setting flow rate for step 1 3 auto mode Time setting for step...

Reviews: