WMS-100 104193 V2.7 - 14.10.2019
Page 30
Operation of the 'cleaning parameters, configuration’ level
Drain valve selection
Setting range
Factory setting
1 = Drain valve 1
2 = Drain valve 2
3 = Drain valve 1+2
E81 Drain valve select. wash. stage 1 (pre-rinse 1)
1 .. 3
1
E82 Drain valve select. wash. stage 2 (pre-rinse 2)
1 .. 3
1
E83 Drain valve select. wash. stage 3 (main wash 1)
1 .. 3
1
E84 Drain valve select. wash. stage 4 (interm. rinse)
1 .. 3
1
E85 Drain valve select. wash. stage 5 (main wash 2)
1 .. 3
1
E86 Drain valve select. wash. stage 6 (final rinse)
1 .. 3
1
E88 Switch mode drain valve 1
0 .. 1
0
0 = normally closed 1 = normally open
E89 Switch mode drain valve 2
0 .. 1
0
0 = normally closed 1 = normally open
Sensor setting
Setting range
Factory setting
E90 Temperature sensor 1
E91 Offset compensation sensor 1
-10 K ...10K
0 K
Servicing / Starting operation for first time
Setting range
Factory setting
E94 One-off start from washing stage
1..5
1
E95 The next x washing stages can be brought forward 0..5
0
using button ‘arrow up' step by step
Display setting
Setting range
Factory setting
E97 Display during cleaning
0..2
0
0 = current programme step, with step down
(use DOWN button to display current temperature)
1= current temperature
(use DOWN button to display current programme step)
2 = automatic, current programme step, with step down,
in heating steps, switch to current temperature