E26 Safety switch present
0 .. 6
0
0 = deactivated
1 = Cleaning only‚ “high-active“ (signal must be present in order to clean)
2 = Cleaning only ‚ “low-active“ (signal must not be present in order to clean)
3 = Milking only‚ “high-active “ (signal must be present in order to milk)
4 = Milking only‚ “low-active “ (signal must not be present in order to milk)
5 = Cleaning “high-active “ - Milking “low-active “
6 = Cleaning “low-active “ - Milking “high-active “
E27 Timeout water intake by level
0,0 .. 999 min.
20 min.
If the level is not reached during the set time, cleaning stops, with subsequent error
message 008.
E28 Short-rinse programme selection
0 .. 7
0
0 = Short-rinse programme deactivated
1 = Pre-rinse 1 only
2 = Pre-rinse 2 only
3 = Main wash 1 + after-rinse
4 = Intermediate rinse only
5 = Main wash 2 + after-rinse
6 = After-rinse only
7 = Manual selection
Number of repetitions of indiv. washing stages:
Setting range
Factory setting
E31 Number of repetitions of washing stage 1
0 .. 5
1
E32 Number of repetitions of washing stage 2
0 .. 5
1
E34 Number of repetitions of washing stage 4
0 .. 5
0
E35 Number of repetitions of washing stage 5
0 .. 1
0
E36 Number of repetitions of washing stage 6
0 .. 5
1
STOP settings
(further via button 5 or digital input)
E38 Stop inserted after which washing stage
0..2
1
0 = no STOP
1 = after washing stage 1
2 = at the end of washing stage 2
E39 Maximum STOP period (timeout)
0 .. 999 min.
0 min.
0 = no timeout
from 1: timeout in minutes
Injection settings
Setting range
Factory setting
E40 Number of alkaline washes before an acidic wash
(only active if washing stage 5 is deactivated)
0* .. 10
3
* Special case: Input “0” = always alkaline, never acidic
Outlet settings
Setting range
Factory setting
E42 Vacuum pump on/off with
„water heating“
0..1
0
0 = off 1 = on
E43 Position of injection
0..2
0
0 = Injection 1
1 = Injection 2
2 = = Beaker dosage (parallel to water intake)
WMS-100 104193 V2.7 - 14.10.2019
Page 28
Operation of the 'cleaning parameters, configuration’ level