2 Safety
2.1 Designated application
The combustion manager W-FM 25 is suitable for use with:
▪
oil burners
▪
gas burners
▪
dual fuel burners.
Improper use could:
▪
endanger the health and safety of the user or third parties,
▪
cause damage to the appliance or other material assets.
2.2 When gas can be smelled
Avoid open flames and spark generation, for example:
▪
do not operate light switches,
▪
do not operate electronic equipment,
▪
do not use mobile telephones.
▶
Open doors and windows.
▶
Close gas isolating valve.
▶
Warn the inhabitants (do not ring door bells).
▶
Leave the building.
▶
Inform the heating company or gas supplier from outside of the building.
2.3 Safety measures
Safety relevant fault conditions must be eliminated immediately.
2.3.1 Normal operation
▪
All labels on the unit must be kept in a legible condition,
▪
the unit should only be operated with its cover in the closed position,
▪
do not touch moving parts during operation,
▪
stipulated settings, service and inspection work should be carried out at regular
intervals.
2.3.2 Electrical connection
For work carried out on live parts:
▪
Observe the accident prevention instructions BGV A3 and adhere to local direc-
tives,
▪
tools in accordance with EN 60900 should be used.