Control.ini
69
All conditions have to be expressed within a round bracket ()
separated with a semicolon. Spaces within the round brackets
are not allowed.
Example:
!rc(d=24;o=12;y=12):!rsn1#
→ December 24th 2012 runs
Show 1 in normal mode.
!rc(s&10):!….#
→ all 10 seconds the downstream command
will be executed.
!rc(w>2;w<7;h=8):!…#
→
from Tuesday till Saturday the
downstream command will be executed precisely at 8 am.
!rc(m&15):!..#
→ at every quarter (0, 15, 30, 45) the
downstream command will be executed.
A real-time command will be executed, as soon as all
conditions within the round bracket are true. This condition has
to become "untrue" once, that the command will be executed
the next time it becomes "true" again.
For example the condition
!rc(s&1):!…#
would be executed
only once, because second modulo 1 is always "true".
!v: Variable events
For basic information about the variables read the chapter
Variable.