Additional safety measures and precautions when working with el
1. Only connect the equipment to regular sources of electric power.
2. Check the cables for darnage before use -never connect damaged cables.
3. Connections must be dry and should not lie on the tl oor .
4. Do not touch the plug with wethands.
5. If an extension cable is used this should be completelyunwound from its drum and should have an adequate
wire cross section, otherwise the cable can overheat (scorch) andcause ashort-circuit;
(Threephase current equipment up to 10 meters long wire cross section 1.5 mm, up to 30 m long 2.5 mm, single-
phase device type Waschbär SE 112/118. ..generally at least 2.5 mm wire cross section.)
Water supply
Connect water hose with Geka coupling on high-pressure cleaner at .
Connect water connection piece.
Fully open water tap.
Water feed pressure min. 2 bar,.max. 4 bar:A pressure reducing va1ve must be incorporatedin the feed
line with higher water mains pressures.
Connection ofthe high.pressure hose
Screw one end of the high-pressure hose onto the pressure output nipple on the device. The other end
ofthe high-pressure hose is screwed to the spray gun.
Cleansant feed and supply
An injector will meter out the cleansant. Connect the cleansant hose to the injektor and place the suction
filter into the cleansant. The quantity of cleansant can be adjusted by turning the hand nut at the cleansant-injektor.
If all the prenamed points are fullfilled, activate the cleansant feed while opening the pressure adjusting nozzle at
the end of the jet pipe. The more the pressure adjusting nozzle is opened the more cleansant will be feed and the
other way around.
The function of the injector takes place only in case of*low pressure*. Feeding takes place only to a max. hose
length of 15 meters. Before using for other purposes consult with the firm of weidner or one of their agencies first.
Protection against freezing
Freeze can destroy equipment which has not been completely emptied of water .The best protection against freeze
is to place the device in a room protected against frost.
Warnings
Do not point the water jet at persons or animals (risk of injuries through pressure and heat as well as irritation of
mucous membranes and acid burn through chemicals ).
Do not point the water jet at the device itself or other electrical components (risk of short-circuits and other
damage ).
The device may not be used in rooms exposed to the risk of explosions.
When using chemicals suitable safety equipment should be worn ( safety goggles, safety overall, safety gloves,
boots etc.).
PIease pay attention to Section " A " of the appendix to VBG 1 35-47, Protection against dangerous chernicals.
Summary of Contents for HWY118 EXT